- Now Manufactured by IET Labs
- 20 Hz to 1 MHz Frequency Range 27,000 Possible Frequency Options
- 0.1% Basic Measurement Accuracy
- Measures 15 Impedance Parameters, DC Resistance, Voltage and Current
- DCR DC Resistance
- 1910 Internal DC Bias Current, Programmable from 0 to 1A
- 1920 Internal DC Bias Voltage, Programmable from 0 to 2 V
- IEEE-488.2,RS-232, handler, and serial printer interfaces all standard
- IET 1910 and 1920 LabView Driver for IEEE-488.2 and RS-232
Estimated Delivery is 2-3 weeks
Repair/Calibration Quote Technical Support Request Two versions of the 1 MHz Precision LCR Meter, the 1910 and 1920
The 1920 1 MHz LCR Meter is the most popular and designed to perform capacitance and impedance measurements on a variety of electronic components and materials over a frequency range from 20 Hz to 1 MHz. The1920 features programmable bias voltage from 1 mV to 2 V for biasing capacitors and other semiconductor devices during measurements.
The 1910 Inductance Analyzer has the same feature as the 1920, with the bias voltage feature being replace by a programmable bias current of up to 1 A. The bias current features makes the1910 designed to perform inductance and impedance measurements on coils and wire wound devices over a frequency range from 20 Hz to 1 MHz.
Emphasis has been placed on ease of use through menu programming, and fast accurate production testing via its remote control capability with RS-232, handler and GPIB interfaces.
15 Different Impedance Parameters/20 Total Parameters Measure and display any two parameters simultaneously, to achieve coverage
and flexibility not previously available.
Automatic Test Sequencing Run up to six different tests in sequence with a single push of the start button. Each test can have different conditions and limits.
Program Storage Test setups can be stored and recalled from internal memory. The front panel can be locked out, with password protection, to ensure procedures are run the same way every time.
Configure instrument and log results to PC IET offers a Window based program that can be downloaded for free. 1900 Virtual Front Panel
Why Buy The 1920 Precision 1MHz LCR Meter?
- For a wide frequency range (to 1MHz) at an affordable price
- When both AC impedance and DC resistance measurements are needed
- For automated production testing using RS232, IEEE-488 & PLC interfaces
- When internal bias current is required for testing coils and inductors
- Configure instrument and log results to PC using the 1900 Virtual Front Panel
If you are looking for a more cost effective or higher preforming LCR Meter such as the IET / QuadTech 7600 Precision LCR Meter or IET / GenRad 1689 Digibridge, See our LCR Meter Selection Guide
1910/1920 Basic Specifications
(See datasheet for full specifications)Measured Parameters and Basic Measurement Accuracy:
| Parameter | Measurement Range | Fast | Medium | Slow |
| Ls,Lp | 0.001 nH to 99.999 H | +/-0.5% | +/-0.25% | +/-0.1% |
| Cs,Cp | 1 pF to 9.9999 F | +/-0.5% | +/-0.25% | +/-0.1% |
| DF | 0.00001 to 99.999 | +/-0.005 | +/-0.0025 | +/-0.001 |
| Q | 0.00000 to 9999.9 | +/-0.005 | +/-0.0025 | +/-0.001 |
| Y,Gp,Bp | 10 nS to 9999.9 S | +/-0.005 | +/-0.0025 | +/-0.001 |
| |Z|,Rs,Rp,Xs,ESR | 0.0001 mΩ to 99.999 MΩ | +/-0.5% | +/-0.25% | +/-0.1% |
| Phase Angle | -180.00 to +179.99 degrees | +/-1.8° | +/-0.9° | +/-0.18° |
| DCR | 0.1 mVto 100 KV | +/-0.5% | +/-0.25% | +/-0.1% |
| DUT AC Voltage | 20 mV to 1.0 V | +/-0.5% | +/-0.25% | +/-0.1% |
| DUT AC Current | 1 μA to 150 mA | +/-0.5% | +/-0.25% | +/-0.1% |
| DUT DC Voltage | 20 mV to 1.0 V | +/-0.5% | +/-0.25% | +/-0.1% |
| DUT DC Current | 1 μA to 150 mA | +/-0.5% | +/-0.25% | +/-0.1% |
*At optimum test signal levels, frequencies, DUT values and without calibration uncertainty. Capacitance (Cs/Cp), Inductance (Ls/Lp), Resistance (Rs/Rp), Dissipation (D) and Quality (Q) Factors, Impedance Z , Admittance Y , Phase Angle (0-), Equivalent Series Resistance (ESR), Conductance (Gp), Reactance (Xs), Susceptance (Bp) Note: s = series, p = parallel, ESR equivalent to Rs
Test Frequency Range: 20 Hz to 1 MHz, Continuous
Test Frequency Resolution: 1 Hz from 20 Hz to 1 kHz, 4 digits >1 kHz
Test Frequency Accuracy: +/- (0.01% +0.02 Hz)
Measurement Speed: Fast: 40 meas/sec Medium: 8 meas/sec Slow 1 meas/sec
Ranging Automatic,Range Hold or user selectable
Trigger internal (automatic), External(via RS-232,IEEE-488.2, Handler interfaces or Manual
Source Impedance 5, 25, 50, 100 ohms selectable
AC Test Signal Voltage: 20 mV to 1.0 V (open circuit) in 5 mV steps
DC Bias Current Internal: 0.0 to 1.0 A in 1 mA steps External: up to 20.0 A
Standard Interfaces IEEE-488.2 • RS-232 • Handler • Serial Printer
Measurement Delay Programmable from 0 to 1000 ms in 1 ms steps
Averaging Programmable from 1 to 1000
Median Value Averaged over last three measurements
Built-in automatic calibration procedure
Test Terminals Front panel, four terminal (BNC) Optional Test Fixtures Available
Dimensions: 17x 5.25x 16in (432x 133x 406 mm)
Weight: 15lbs (8kg) net, 21lbs (9.9kg) shipped
-
Data Sheet
This document explains the features, options, Specifications and option models for this item.
-
Product Manual
Specifications and option models for this item. This document contains the technical product manual and guidelines.
-
Driver
Software drivers to allow this instrument to work with your computer
-
Application Notes
Application notes and technical resources for this instrument
-

NIST Traceable Calibration Cert (Included)
+ $0.00
-

ISO-17025 Accredited Calibration with Test Data
+ $150.00
-

1910/1920 Application Wizard with RS-232 Cable
+ $110.00
-

1689-9600 Remote Test Fixture
+ $589.00
-

1700-03 Kelvin Test Leads
+ $185.00
-

7000-04 Alligator Clip Leads, 1 Meter
+ $335.00
-

1689-9602 BNC-BNC Extender Cable
+ $245.00
-

1689-9602-2 Meter BNC-BNC Extender Cable
+ $265.00
-

7000-05 Chip Component Tweezers
+ $1365.00
-

2000-16 Rack Mount Kit for 1910/1920
+ $250.00
-

Rigid Dielectric Cell LD-03
+ $8585.00
-

High Temperature Rigid Dielectric Cell LD-3T
+ $9875.00
-

Liquid Dielectric Cell 350G
+ $7985.00
-

Powder, Paste and Liquid Cell MC-100
+ $8895.00
-

950038 1900 Series Calibration Kit
+ $4875.00
Product Categories
-
http://www.ietlabs.com/decaderes.htmlResistance
-
http://www.ietlabs.com/decaderes/decade-resistor.htmlDecade Resistor
-
http://www.ietlabs.com/decaderes/resistance-standard.htmlResistance Standard
-
http://www.ietlabs.com/decaderes/resistance-meter.htmlOhmmeter
-
-
http://www.ietlabs.com/capacitance.htmlCapacitance
-
http://www.ietlabs.com/capacitance/decade-capacitor.htmlDecade Capacitor
-
http://www.ietlabs.com/capacitance/capacitance-standard.htmlCapacitance Standard
-
http://www.ietlabs.com/capacitance/capacitance-meter-bridge.htmlCapacitance Bridges
-
-
http://www.ietlabs.com/inductance.htmlInductance
-
http://www.ietlabs.com/inductance/decade-inductor.htmlDecade Inductor
-
http://www.ietlabs.com/inductance/inductance-standard.htmlInductance Standard
-
http://www.ietlabs.com/inductance/inductance-meter.htmlInductance Meter
-
-
http://www.ietlabs.com/decadebox.htmlDecade Boxes
-
http://www.ietlabs.com/rtds.htmlRTD Simulators
-
http://www.ietlabs.com/micro-ohmmeter.htmlMicro-Ohmmeters
-
http://www.ietlabs.com/ohmmeters.htmlMegohmmeters
-
http://www.ietlabs.com/digibridges.htmlImpedance Meters & Bridges
-
http://www.ietlabs.com/lcr-meter.htmlLCR Meter
-
http://www.ietlabs.com/variac.htmlVariacs
-
http://www.ietlabs.com/stroboscope.htmlStroboscopes
-
http://www.ietlabs.com/sound-level-meter.htmlAudio
-
http://www.ietlabs.com/voltage-divider.htmlVoltage Dividers
-
http://www.ietlabs.com/decadevi.htmlVoltage & Current Sources
-
http://www.ietlabs.com/gr874-connectors.htmlGR 874 / Test Leads
-
http://www.ietlabs.com/dielectric-cells.htmlDielectric Test Cells
-
http://www.ietlabs.com/scrollingcatalog.htmlScrolling Catalog
- Home
- Products
- Calibration & Repair
- Company
- Contact Us
- Terms/Privacy Policy
- Request Quote
- Technical Support
- Site Map
PHONE: (516) 334-5959 FAX: (516) 334-5988 SALES@IETLABS.COM