GenRad 1404 Series Primary Standard Capacitors
- Available in 10 pF, 100 pF,1000 pF, 5000 pF 10,000 pF
- 20 ppm/year stability, history has shown this to be a very conservative
specification
- The national laboratory standard for capacitance
- For calibrating highest level standards
- Standard for dissipation factor
- 5 year warranty included
GenRad 1409 Series Standard Capacitor
- Values 0.001 µF (100 nF) to 1000 µF
- Stability as good as ±0.01 %/year
- Two-to-five terminal configuration, depending on model
- Calibration accredited to ISO-17025 included
- 3 year warranty included
GenRad 1412-BC Decade Capacitance Box
- Range from 50 pF to 1.11115 µF
- Resolution better than 1 pF
- Accuracy 0.5% + 5 pF
- Low loss, leakage, dielectric absorption
- Verification of calibration of LCR meters, multimeters, and instrumentation
Genrad 1413 Precison Decade Capacitor
- Range from 1 pF to 1.11111 µF
- High accuracy of 0.05% + 0.5 pF
- Excellent Stability 100 ppm per year
- The trusted lab standard for capacitance
- 3-Terminal shielded construction
GenRad 1417 Capacitance Standard 1 uF - 1 F
- 7 Switch-Selected Standard Capacitance Values: 1 µF, 10 µF, 100 µF, 1 mF, 10 mF,100 mF, 1 F
- 3 Switch-Selected Test Frequencies: 100 Hz, 120 Hz, 1 kHz
- 0.25% direct-reading capacitance accuracy
- 0.1% or better ratio accuracy
GenRad 1422 Series Variable Air Capacitors
- Range as low as 0.002 pF and as high as 1150 pF (Depending on Model)
- Stability: better than 0.02% full scale per year
- Settable to 40 ppm
- Low temperature coefficient, low losses
- Wide selection to suit needs
GenRad 1423-A Decade Capacitor
- Range 100pF - 1.111 µF
- ±0.05% accuracy
- two- or three-terminal connection
- Ideal for calibration of 2-terminal handheld DMMs
GenRad 1620 Capacitance Bridge
- 10-5pF to 11.1 µF, 2-or 3-terminal
- frequency range 20 Hz -20 kHz (or higher)
- 0.01% accuracy, 1-ppm resolution
- reads dissipation factor or conductance
- combines GenRad 1615 Capacitance Bridge, 1232-A Null Detector & 1311-A Oscillator
GenRad 1621 Capacitance Bridge
- Range 10-7 pF to 10 µF, 12-digit readout
- 10-ppm basic accuracy
- frequency range 10 Hz - 100 kHz
- combines GenRad 1616 Capacitance Bridge, 1238-A Null Detector & 1316 Oscillator
GenRad 1659 Digibridge
- 0.1% measurement accuracy
- 4 test frequencies 100 Hz to 10 kHz
- 5 impedance parameters
- Built-in test fixture
GenRad 1689 Precision Impedance Meter
- The world's standard for AC resistance, low frequency inductance and Capacitance measurement
- 0.02% Measurement Accuracy and +/- 0.0001 Df
- Programmable Frequency 12 Hz - 100 kHz
- Widely accepted impedance meter in a metrology environment
- 1689 has a built-in 4 terminal kelvin fixture for testing axial and radial components
- 1689M has four BNC connectors for use with a wide variety of standard accessories
GenRad 1693 Precision LCR Meter
- The world's standard for ac resistance, low frequency inductance and capacitance measurement in a metrology environment
- 0.02% measurement accuracy and +/- 0.0001 Df
- Programmable frequency 12 Hz - 200 kHz
- Extremely reliable can last up to 30+ years
IET 1403-1pF-BNC High Frequency Standard Capacitor
- Available in values from 0.001 pF - 1000 pF
- Excellent performance at high frequencies
- ISO-17025 accredited calibration included with the standard
- NEW 1403-1pF-BNC version
Consult IET Labs, Inc for pricing information