Capacitance Bridges
-
GenRad 1689 Precision Impedance Meter
- The world's standard for AC Resistance, Low Frequency Inductance and Capacitance measurement
- 0.02% Measurement Accuracy and +/- 0.0001 Df
- Programmable Frequency 12 Hz - 100 kHz
- Widely accepted impedance meter in a metrology environment
- 1689 has a built-in 4 terminal kelvin fixture for testing axial and radial components
- 1689M has four BNC connectors for use with a wide variety of standard accessories
-
IET/QuadTech 7600 Plus Precision LCR Meter
- Now Manufactured by IET Labs
- Measures 14 Impedance Parameters (2 simultaneously)
- 0.05% Basic Measurement Accuracy
- Programmable Frequencies from 10Hz to 2MHz
- AC Test Voltage Programmable from 20mV to 5V
- DC Bias Voltage, 2V Internal or 0 to 200V External
- Fast Measurement Speeds up to 120/Second
- Automatic Open/Short Zeroing Eliminates Connection Errors
- High Resolution LCD with 7 Digit Display
- 14 Hi/Lo Sorting Bins for Pass/Fail Testing
IET/QuadTech 1910/1920 1 MHz LCR Meter
- Now Manufactured by IET Labs
- 20 Hz to 1 MHz Frequency Range 27,000 Possible Frequency Options
- 0.1% Basic Measurement Accuracy
- Measures 15 Impedance Parameters, DC Resistance, Voltage and Current
- DCR DC Resistance
DE-5000 Handheld LCR Meter
- Precision Handheld LCR Meter: up to 0.3% Accuracy
- Wide Range of Selectable test frequencies: 100 Hz / 120 Hz / 1 kHz / 10 kHz / 100 kHz
- Measures: Resistance, Capacitance, Inductance, Dissipation Factor, Quality and Phase Angle
- USB interface for Data Storage of LCR Results
- Allows for 4-Wire Kelvin Measurement to factor out impedance of test leads
GenRad 1693 Precision LCR Meter
- The world's standard for AC Resistance, Low Frequency Inductance and Capacitance measurement in a metrology environment
- 0.02% Measurement Accuracy and +/- 0.0001 Df
- Programmable Frequency 12 Hz - 200 kHz
- Extremely Reliable can last up to 30+ years
GenRad 1620 Capacitance Bridge
- 10-5pF to 11.1 µF, 2-or 3-terminal
- frequency range 20 Hz -20 kHz (or higher)
- 0.01% accuracy, 1-ppm resolution
- reads dissipation factor or conductance
- combines GenRad 1615 Capacitance Bridge, 1232-A Null Detector & 1311-A Oscillator
GenRad 1692 Benchtop LCR Meter
- 0.05% Measurement Accuracy
- 5 Test Frequencies 100Hz to 100kHz
- 5 Impedance Parameters
- Built-in Test Fixture
GenRad 1659 Digibridge
- 0.1% Measurement Accuracy
- Cost-Effective Solution
- 4 Test Frequencies 100Hz to 10kHz
- 5 Impedance Parameters
- Built-in Test Fixture
GenRad 1621 Capacitance Bridge
- Range 10-7 pF to 10 µF, 12-digit readout
- 10-ppm basic accuracy
- frequency range 10 Hz - 100 kHz
- combines GenRad 1616 Capacitance Bridge, 1238-A Null Detector & 1316 Oscillator