Decade Boxes

Your Decade Box Source...

IET manufactures resistance, capacitance, and inductance decade boxes that cover a broad range of applications for the field, the laboratory or automated stations. Hundreds of models are available from the highest precision and performance to cost effective. If you don’t find the decade box you need from the standard models, we will build it for you.

IET Labs, maintains some of the finest R, L and C calibration standards in the World. IET Labs continues to manufacture and support a wide variety of products that were originally manufactured by GenRad, esi, QuadTech and others. The majority of IET’s products are manufactured with pride in the USA.

Items 16 to 28 of 28 total

per page
Page:
  1. 1
  2. 2

Set Descending Direction
  1. esi RS925

    esi RS925D Resistance Decade

    • High accuracy - 20 ppm + 0.5 mΩ
    • High stability - 20 ppm + 0.5 mΩ
    • Resistance from 10 mΩ to 1.1 MΩ
    • 20 μΩ resolution 
    • Precise fixed minimum resistance
  2. HARS-LX-10-0.001

    HARS-LX Series Decade Resistance Substituter Lab Standard

    • High accuracy - as good as 20 ppm
    • High stability - as good as 5 ppm/yr
    • Over 55 models available with resistance from 1 mΩ to 121.1 MΩ
    • Resolution as good 1 mΩ with a fixed decade or 20 μΩ with a rheostat.
  3. HRRS Decade Resistor 4 Dial

    HRRS Series High Resistance Decade Box

    • Resistance from 100 Ω to 100 GΩ
    • High-accuracy: up to .01%, 3 Accuracy Classes Available
    • Voltage up to 2000 V
    • Excellent TC: as low as 5 ppm/°C
  4. HRRS-5-100M-5kV

    HRRS-5 kV & 10 kV Series - High Resistance Decade Box

    • Resistance from 1 Ω to 10 TΩ +
    • High-accuracy: up to .01%; 3 Accuracy Classes
    • Max voltage of 5 kV or 10 kV; 2 Series
    • Ideal for the calibration of meggers
  5. esi/Tegam DB62 Decade Resistance Box

    esi / Tegam DB62 Decade Resistor

    • Precision accuracy of ±(0.01% + 2 mΩ)
    • Resistance range from 0.01 Ω to 11.1111 MΩ
    • 4 models available, each covering six decades
    • High-performance solid silver-alloy contacts
    • Low zero resistance < 6mΩ
  6. Decade Resistor 7 Dial

    GenRad 1433 Series Decade Resistor

    • Precision accuracy of +0.01%
    • Resistance range from 1 mΩ to 111.11111111 MΩ
    • 36 models available, 3 to 11 dials
    • Long life switches with solid silver contacts
  7. Megger Calibration Set of High Resistance Standards

    VRS-100 Series High Resistance Standards

    • Set of nine, ten or eleven resistors - 1 kΩ, 10 kΩ, 100 kΩ,1 MΩ, 10 MΩ, 100 MΩ, 1 GΩ, 10 GΩ, 100 GΩ, 1 TΩ and 10 TΩ , open circuit (Depending on model)
    • High Accuracy - up to 20 ppm
    • Standard voltage: up to 5 kV (voltages of 10 kV are available)
    • Excellent for calibration of Meggers
  8. GenRad 1423-A Decade Capacitor

    GenRad 1423-A Decade Capacitor

    • Range 100pF - 1.111 µF
    • ±0.05% accuracy
    • two- or three-terminal connection
  9. OS-270 OhmSOURCE with Leads

    ohmSource Resistance Decade Box / RTD Simulator

    • The revolutionary ohmSOURCE Microprocessor Controlled Resistance Decade Boxes are like nothing you have ever seen before!
    • Two cost-effective models available
    • Accuracy's as tight as 0.01%, with resolution as good as 0.01Ω
    • Engineered as an ideal RTD Calibrator 
  10. 1422-CB 3-Terminal Air Capacitor

    GenRad 1422 Series Variable Air Capacitors

    • Range as low as 0.002 pF and as high as 1150 pF (Depending on Model)
    • Stability: better than 0.02% full scale per year
    • Settable to 40 ppm
    • Low temperature coefficient, low losses
    • Wide selection to suit needs
  11. 1412-B Decade Capacitor

    GenRad 1419 Series Decade Capacitor

    • Range from 100 pF to 1.1 µF
    • Choice of 3 models
    • Accuracy as good as 0.5%
    • Capacitance and dissipation factor vary only slightly with frequency from dc through the audio frequency range.
  12. DRS-900

    DRS-900 High Power Decade Resistor

    • Resistance from 1 mΩ to 1 MΩ
    • Standard Accuracy: (1% + 20 mΩ) 
    • Power Rating : 225 W/decade, 250 W max. or higher
    • Voltage Rating: 1000 V or higher
    • Rack mounting standard
    • Special and custom configurations available
    • Replacment for the Clarostat 240C
  13. 1492 Precision Decade Inductor

    GenRad 1492 Decade Inductor

    • Inductance range from 1 µH to 11 H
    • Toroidal cores for small mutual inductance and minimal effect from external fields
    • High-accuracy: ±(1% + 0.75 µH)
    • 7 decade switches

Items 16 to 28 of 28 total

per page
Page:
  1. 1
  2. 2

Set Descending Direction