Resistance

15 Item(s)

per page

Set Descending Direction
  1. esi SR1010 Resistance Transfer Standard

    esi SR1010 Resistance Transfer Standard

    • Resistance Transfer Standards available in the following values 1 Ω, 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ
    • Initial Accuracy... ± 20PPM of nominal value matched within 10PPM
    • Transfer Accuracy... ± (1PPM + 0.1uΩ at parallel value) for 100:1
    • Transfer Accuracy... ± (1PPM + 1uΩ at series parallel value) for 10:1
    • Long Term Accuracy... ± 50PPM of nominal value
    • Calibration Accuracy... ± 10PPM
  2. SR-1050 Transfer Standard

    esi SR1050 Series 1M & 10 M Resistance Transfer Standard

    • Resistance Values 1 MΩ & 10 MΩ
    • Initial Accuracy... ± 25 or 30 ppm of nominal value matched within 10 ppm
    • Transfer Accuracy... ± 2 ppm (Typical Short-term Repeatability)
    • Calibration Accuracy... ± 10 or 15 ppm
  3. SRX1 Series NAVAIR Resistance Standard

    SRX1 Series NAVAIR Resistance Standard

    • Range from 1 Ω - 1 MΩ
    • Stabilities as good as 5 ppm
    • Minimal Change from power cycling
    • The US Navy's Resistance Standard
  4. Calibration Resistor

    esi SR1 Calibration Resistor

    • New Design, With Improved Specifications
    • Versatile working Calibration Resistor
    • Laboratory standard of high accuracy and stability
    • Adjusted to within 20 ppm of nominal
    • 50 ppm long-term accuracy for most values
  5. SRX 4-Terminal

    SRX/SRC Series Economical Resistance Standard

    • Wide range of values - 1 mΩ to 10 TΩ
    • Very stable - up to 10 ppm/yr
    • ISO-17025 Accredited Calibration Included
    • 3 Year Warranty Included
    • Excellent TC - as low as 1 ppm/°C
  6. DC Current Shunt

    DCCS DC Current Shunt Series

    • Allows for High Current Calibration, up to 60 A
    • Resistances ranges from 100 µΩ - 1 kΩ
    • High Accuracy 0.02%
    • Suitable for Direct Current & Technical Frequencies
    • Oil-Filled Design Ensures Great Long Term Stability <0.01% Over Many Years
  7. HARS-LX-10-0.001

    HARS-LX Series Decade Resistance Substituter Lab Standard

    • High accuracy - as good as 20 ppm
    • High stability - as good as 5 ppm/yr
    • Over 55 models available with resistance from 1 mΩ to 121.1 MΩ
    • Resolution as good 1 mΩ with a fixed decade or 20 μΩ with a rheostat.
  8. Precision Resistance Standards

    SRL Series Precision Resistance Standard

    • Very stable - up to 2 ppm/yr
    • Wide range of values - 1 mΩ to 10 TΩ,
    • Used by National Measurment Institutes across the world
    • 3 Year Warranty Included
  9. LOM-530 Micro-Ohmmeter Calibration Kit

    LOM-530 Micro-Ohmmeter Calibration Kit

    • Complete set of (5) working standard resistors for calibration of micro-ohmmeters. 
    • Resistance values can be custom modified per your requirement.
    • Calibrates a wide verity of micro-ohmmeters from various manufacturers
  10. HATS-LR Low Resistance Transfer Standard

    HATS-LR Low Resistance Transfer Standard

    • Values from 1 Ω - 100 kΩ
    • Initial Accuracy... As good as 10 ppm of nominal value
    • Transfer Accuracy... ± (1 ppm + 0.1uΩ at parallel value) for 10:1 & 100:1 ratios
    • Long Term Accuracy... ± 10 ppm/year
    • Calibration Accuracy... ± 5 ppm
  11. Transfer Standard

    HATS-Y Series High Resistance Transfer Standard

    • Resistance Values 100 kΩ, 1 MΩ, 10 MΩ, 100 MΩ
    • Initial Accuracy...As good as 10 ppm nominal value matched within 10 ppm
    • Transfer Accuracy... ± 2 ppm (Typical Short-term Repeatability)
    • 1 Year Stability : As good as 10 ppm
  12. Megger Calibration Set of High Resistance Standards

    VRS-100 Series High Resistance Standards

    • Set of nine, ten or eleven resistors - 1 kΩ, 10 kΩ, 100 kΩ,1 MΩ, 10 MΩ, 100 MΩ, 1 GΩ, 10 GΩ, 100 GΩ, 1 TΩ and 10 TΩ , open circuit (Depending on model)
    • High Accuracy - up to 20 ppm
    • Standard voltage: up to 5 kV (voltages of 10 kV are available)
    • Excellent for Meggers
  13. SRR High Accuracy Standard Resistors

    SRR Series High Accuracy Standard Resistor

    • High accuracy four-terminal standard resistors
    • Resistance Value of: 0.0001 Ω, 0.001 Ω, 0.01 Ω, 0.1 Ω
  14. Resistance Transfer Standard

    esi SR1030 Series Oil Immersed Transfer Standard

    • Resistance Values of 1 Ω - 100 kΩ
    • Initial Accuracy... ± 20 PPM of nominal value matched within 10 PPM
    • Transfer Accuracy... ± (1 PPM + 0.1uΩ at parallel value) for 100:1
    • Long Term Accuracy... ± 50 PPM of nominal value
    • Calibration Accuracy... ± 10 PPM
  15. esi SR102, SR103, SR104

    SR102/103/104 Series

    • Highest accuracy (1 ppm/yr) and stability (±0.5 ppm/yr typical) of any resistance standard
    • Lowest temperature coefficients (< 0.1 ppm/ºC)
    • Available in 3 models: 100Ω, 1000 Ω, 10,000Ω.
    • Has remained the foremost resistance standard, with no equivalent, for over 35 years
    • 5 Year Warranty Included

15 Item(s)

per page

Set Descending Direction