Resistance
-
esi SR1050 Series 1M & 10 M Resistance Transfer Standard
- Resistance Values 1 MΩ & 10 MΩ
- Initial Accuracy... ± 25 or 30 ppm of nominal value matched within 10 ppm
- Transfer Accuracy... ± 2 ppm (Typical Short-term Repeatability)
- Calibration Accuracy... ± 10 or 15 ppm
-
SRR Series Precision Low Reichanstalt Type Standard Resistor
- Reichanstalt Type four-terminal resistors
- Resistance Value of: 0.0001 Ω, 0.001 Ω, 0.01 Ω, 0.1 Ω
-
esi SR1030 Series Oil Immersed Transfer Standard
- Resistance Values of 1 Ω - 100 kΩ
- Initial Accuracy... ± 20 PPM of nominal value matched within 10 PPM
- Transfer Accuracy... ± (1 PPM + 0.1uΩ at parallel value) for 100:1
- Long Term Accuracy... ± 50 PPM of nominal value
- Calibration Accuracy... ± 10 PPM
-
VRS-100 Series High Resistance Standards
- Set of nine, ten or eleven resistors - 1 kΩ, 10 kΩ, 100 kΩ,1 MΩ, 10 MΩ, 100 MΩ, 1 GΩ, 10 GΩ, 100 GΩ, 1 TΩ and 10 TΩ , open circuit (Depending on model)
- High Accuracy - up to 20 ppm
- Standard voltage: up to 5 kV (voltages of 10 kV are available)
- Excellent for Meggers
-
HATS-Y Series High Resistance Transfer Standard
- Resistance Values 100 kΩ, 1 MΩ, 10 MΩ, 100 MΩ
- Initial Accuracy...As good as 10 ppm nominal value matched within 10 ppm
- Transfer Accuracy... ± 2 ppm (Typical Short-term Repeatability)
- 1 Year Stability : As good as 10 ppm
-
HATS-LR Low Resistance Transfer Standard
- Values from 1 Ω - 100 kΩ
- Initial Accuracy... As good as 10 ppm of nominal value
- Transfer Accuracy... ± (1 ppm + 0.1uΩ at parallel value) for 10:1 & 100:1 ratios
- Long Term Accuracy... ± 10 ppm/year
- Calibration Accuracy... ± 5 ppm
-
esi SR1010 Resistance Transfer Standard
- Resistance Transfer Standards available in the following values 1 Ω, 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ
- Initial Accuracy... ± 20PPM of nominal value matched within 10PPM
- Transfer Accuracy... ± (1PPM + 0.1uΩ at parallel value) for 100:1
- Transfer Accuracy... ± (1PPM + 1uΩ at series parallel value) for 10:1
- Long Term Accuracy... ± 50PPM of nominal value
- Calibration Accuracy... ± 10PPM
-
LOM-530 Micro-Ohmmeter Calibration Kit
- Complete set of (5) working standard resistors for calibration of micro-ohmmeters.
- Resistance values can be custom modified per your requirement.
- Calibrates a wide verity of micro-ohmmeters from various manufacturers
-
SRL Series Precision Resistance Standard
- Very stable - up to 2 ppm/yr
- Wide range of values - 1 mΩ to 10 TΩ,
- Used by National Measurment Institutes across the world
- 3 Year Warranty Included
-
SRX1 Series NAVAIR Resistance Standard
- Range from 1 Ω - 1 MΩ
- Stabilities as good as 5 ppm
- Minimal Change from power cycling
- The US Navy's Resistance Standard
-
DCCS DC Current Shunt Series
- Allows for High Current Calibration, up to 60 A
- Resistances ranges from 100 µΩ - 1 kΩ
- High Accuracy 0.02%
- Suitable for Direct Current & Technical Frequencies
- Oil-Filled Design Ensures Great Long Term Stability <0.01% Over Many Years
-
SRX/SRC Series Economical Resistance Standard
- Wide range of values - 1 mΩ to 10 TΩ
- Very stable - up to 10 ppm/yr
- ISO-17025 Accredited Calibration Included
- 3 Year Warranty Included
- Excellent TC - as low as 1 ppm/°C
-
esi SR1 Standard Resistor
- New Design, With Improved Specifications
- Versatile working standard
- Laboratory standard of high accuracy and stability
- Adjusted to within 20 ppm of nominal
- 50 ppm long-term accuracy for most values
-
SR102/103/104 Series
- Highest accuracy (1 ppm/yr) and stability (±0.5 ppm/yr typical) of any resistance standard
- Lowest temperature coefficients (< 0.1 ppm/ºC)
- Available in 3 models: 100Ω, 1000 Ω, 10,000Ω.
- Has remained the foremost resistance standard, with no equivalent, for over 35 years
- 5 Year Warranty Included
-
HARS-LX Series Decade Resistance Substituter Lab Standard
- High accuracy - as good as 20 ppm
- High stability - as good as 5 ppm/yr
- Over 55 models available with resistance from 1 mΩ to 121.1 MΩ
- Resolution as good 1 mΩ with a fixed decade or 20 μΩ with a rheostat.