Resistance

Items 1 to 15 of 18 total

per page
Page:
  1. 1
  2. 2

Set Descending Direction
  1. RS-201W

    RS Series Resistance Substitution Box

    • Accurate 0.1% to 1%
    • Wide range from 0.01 Ω - 100 M&Omega (Depending on Model)
    • Broad choice of standard and optional models with many powerful features
    • Compact, convenient, and rugged
  2. RCS Series Resistance & Capacitance Box

    RCS Series Resistance & Capacitance Box

    • Combination of Resistance and Capacitance Deacade Box
    • Accurate 0.1% to 4% (Depending on Model)
    • Capacitance Range 100 pF - 100 µF
    • Resistance Range 1 Ω - 10 MΩ
    • Compact, convenient, and rugged
  3. Resistance Decade Box

    HARS Series Resistance Decade Box

    • Resistance from 1 mΩ; to 111 MΩ!
    • Available in double-power version: HARS-X2
    • Wide choice: single through 11 decade units
    • High accuracy - 0.01% (100 ppm) or 0.1% depending on model;
  4. Decade Resistor 7 Dial

    GenRad 1433 Series Decade Resistor

    • Precision accuracy of +0.01%
    • Resistance range from 1 mΩ to 111.11111111 MΩ
    • 36 models available, 3 to 11 dials
    • Long life switches with solid silver contacts
  5. SRX 4-Terminal

    SRX/SRC Series Economical Resistance Standard

    • Wide range of values - 1 mΩ to 10 TΩ
    • Very stable - up to 10 ppm/yr
    • ISO-17025 Accredited Calibration Included
    • 3 Year Warranty Included
    • Excellent TC - as low as 1 ppm/°C
  6. SR1-1K Calibration Resistor

    esi SR1 Calibration Resistor

    • New Design, With Improved Specifications
    • Versatile working Calibration Resistor
    • Laboratory standard of high accuracy and stability
    • Adjusted to within 20 ppm of nominal
    • 50 ppm long-term accuracy for most values
  7. DC Current Shunt

    DCCS DC Current Shunt Series

    • Allows for High Current Calibration, up to 60 A
    • Resistances ranges from 100 µΩ - 1 kΩ
    • High Accuracy 0.02%
    • Suitable for Direct Current & Technical Frequencies
    • Oil-Filled Design Ensures Great Long Term Stability <0.01% Over Many Years
  8. HRRS Decade Resistor 4 Dial

    HRRS Series High Resistance Decade Box

    • Resistance from 100 Ω to 100 GΩ
    • High-accuracy: up to .01%, 3 Accuracy Classes Available
    • Voltage up to 2000 V
    • Excellent TC: as low as 5 ppm/°C
  9. HPRS-F-7-0.001 High Power Decade Resistance Box

    HPRS Series High Power Resistance Decade Box

    • Resistance from 1 mΩ to 10 MΩ
    • Power Rating : 225 W/decade, 250 W max. or higher (Contact IET for Custom Higher Power Units)
    • Accuracy: 0.5% or 1%
    • Special and custom configurations available
  10. HARS-LX-10-0.001

    HARS-LX Series Decade Resistance Substituter Lab Standard

    • High accuracy - as good as 20 ppm
    • High stability - as good as 5 ppm/yr
    • Over 55 models available with resistance from 1 mΩ to 121.1 MΩ
    • Resolution as good 1 mΩ with a fixed decade or 20 μΩ with a rheostat.
  11. SRL-10K Precision Resistance Standard

    SRL Series Precision Resistance Standard

    • Very stable - up to 2 ppm/yr
    • Wide range of values - 1 mΩ to 1.9 TΩ,
    • Used by National Measurment Institutes across the world
    • 3 Year Warranty Included
  12. HRRS-5-100M-5kV

    HRRS-5 kV & 10 kV Series - High Resistance Decade Box

    • Resistance from 1 Ω to 10 TΩ +
    • High-accuracy: up to .01%; 3 Accuracy Classes
    • Max voltage of 5 kV or 10 kV; 2 Series
    • Ideal for the calibration of meggers
  13. SR1010 Resistance Transfer Standard

    esi SR1010 Resistance Transfer Standard

    • Resistance Transfer Standards available in the following values 1 Ω, 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ
    • Initial Accuracy... ± 20PPM of nominal value matched within 10PPM
    • Transfer Accuracy... ± (1PPM + 0.1uΩ at parallel value) for 100:1
    • Transfer Accuracy... ± (1PPM + 1uΩ at series parallel value) for 10:1
    • Long Term Accuracy... ± 50PPM of nominal value
    • Calibration Accuracy... ± 10PPM
  14. SRR High Accuracy Standard Resistors

    SRR Series High Accuracy Standard Resistor

    • High accuracy four-terminal standard resistors
    • Resistance Value of: 0.0001 Ω, 0.001 Ω, 0.01 Ω, 0.1 Ω
  15. Megger Calibration Set of High Resistance Standards

    VRS-100 Series High Resistance Standards

    • Set of nine, ten or eleven resistors - 1 kΩ, 10 kΩ, 100 kΩ,1 MΩ, 10 MΩ, 100 MΩ, 1 GΩ, 10 GΩ, 100 GΩ, 1 TΩ and 10 TΩ , open circuit (Depending on model)
    • High Accuracy - up to 20 ppm
    • Standard voltage: up to 5 kV (voltages of 10 kV are available)
    • Excellent for calibration of Meggers

Items 1 to 15 of 18 total

per page
Page:
  1. 1
  2. 2

Set Descending Direction