  1. HRRS-7 Decade

    HRRS-5 kV & 10 kV Series - High Resistance Decade Box

    • Resistance from 1 Ω to 10 TΩ +
    • High-accuracy: up to .01%; 3 Accuracy Classes
    • Max voltage of 5 kV or 10 kV; 2 Series
    • Ideal for the calibration of meggers
    • Low voltage coefficient: as low as 0.2 ppm/V
    • High-stability: up to 10 ppm/yr
    • Special and custom configurations available
  2. HARS-LX Series Decade Resistance Substituter Lab Standard

    HARS-LX Series Decade Resistance Substituter Lab Standard

    • High accuracy - as good as 20 ppm
    • High stability - as good as 5 ppm/yr
    • Over 55 models available with resistance from 1 mΩ to 121.1 MΩ
    • Resolution as good 1 mΩ with a fixed decade or 20 μΩ with a rheostat.
  3. HPRS Series High Power Resistance Decade Box

    HPRS Series High Power Resistance Decade Box

    • Resistance from 1 mΩ to 10 MΩ
    • Power Rating : 225 W/decade, 250 W max. or higher (Contact IET for Custom Higher Power Units)
    • Accuracy: 0.5% or 1%
    • Voltage Rating: 1000 V or higher
    • Special and custom configurations available
  4. RS-201W

    RS Series Resistance Substitution Box

    • Accurate 0.1% to 1%
    • Wide range from 0.01 Ω - 100 MΩ
    • Broad choice of standard and optional models with many powerful features
    • Compact, convenient, and rugged
  5. RCS Series Resistance & Capacitance Box

    RCS Series Resistance & Capacitance Box

    • Combination of Resistance and Capacitance Deacade Box
    • Accurate 0.1% to 4% (Depending on Model)
    • Capacitance Range 100 pF - 100 µF
    • Resistance Range 1 Ω - 10 MΩ
    • Compact, convenient, and rugged
  6. Resistance Decade Box

    HARS Series Resistance Decade Box

    • Resistance from 1 mΩ to 111 MΩ
    • Available in double-power version: HARS-X2
    • Wide choice: single through 11 decade units
    • High accuracy - 0.01% (100 ppm)
      • HARS-X: ±(0.01% + 2 mΩ)
      • HARS-B: ±(0.1% + 4 mΩ)
  7. Decade Resistor 9 Dial

    GenRad 1433 Series Decade Resistor

    • Precision accuracy of +0.01%
    • Resistance range from 1 mΩ to 111.11111111 MΩ
    • 36 models available, 3 to 11 dials
    • Long life switches with solid silver contacts
    • Excellent frequency characteristics
  8. OhmSOURCE with Leads

    ohmSource Resistance Decade Box / RTD Simulator

    • The revolutionary ohmSOURCE Microprocessor Controlled Resistance Decade Boxes are like nothing you have ever seen before!
    • Two cost-effective models available
    • Accuracy's as tight as 0.01%, with resolution as good as 0.01Ω
    • Engineered as an ideal RTD Calibrator 
  9. HRRS Series High Resistance Decade Box

    HRRS Series High Resistance Decade Box

    • Resistance from 100 Ω to 100 GΩ
    • High-accuracy: up to .01%, 3 Accuracy Classes Available
    • Voltage up to 2000 V
    • Excellent TC: as low as 5 ppm/°C
    • Low voltage coefficient: as low as 0.2 ppm/V
    • High-performance solid silver-alloy switches
    • Rack mounting available
  10. RTD Simulator

    RTD Series - Precision RTD Simulator

    • Highest accuracy, highest stability, lowest TC of any RTD Simulator available
    • Accuracy for Z Series: 0.005% (0.012 ºC for PT 100)
    • Resolution: 1 mΩ (0.0025 ºC for PT 100)
    • Stability 0.0002% for 24 hours; 0.0001% for 12 months
  11. esi / Tegam DB62 Decade Resistor

    esi / Tegam DB62 Decade Resistor

    • Precision accuracy of ±(0.01% + 2 mΩ)
    • Resistance range from 0.01 Ω to 11.1111 MΩ
    • 4 models available, each covering six decades
    • High-performance solid silver-alloy contacts
    • Low zero resistance < 6mΩ
  12. HATS-LR Low Resistance Transfer Standard

    HATS-LR Low Resistance Transfer Standard

    • Values from 1 Ω - 100 kΩ
    • Initial Accuracy... As good as 10 ppm of nominal value
    • Transfer Accuracy... ± (1 ppm + 0.1uΩ at parallel value) for 10:1 & 100:1 ratios
    • Long Term Accuracy... ± 10 ppm/year
    • Calibration Accuracy... ± 5 ppm
  13. esi SR1010 Resistance Transfer Standard

    esi SR1010 Resistance Transfer Standard

    • Resistance Transfer Standards available in the following values 1 Ω, 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ
    • Initial Accuracy... ± 20PPM of nominal value matched within 10PPM
    • Transfer Accuracy... ± (1PPM + 0.1uΩ at parallel value) for 100:1
    • Transfer Accuracy... ± (1PPM + 1uΩ at series parallel value) for 10:1
    • Long Term Accuracy... ± 50PPM of nominal value
    • Calibration Accuracy... ± 10PPM
  14. Transfer Standard

    HATS-Y Series High Resistance Transfer Standard

    • Resistance Values 100 kΩ, 1 MΩ, 10 MΩ, 100 MΩ
    • Initial Accuracy...As good as 10 ppm nominal value matched within 10 ppm
    • Transfer Accuracy... ± 2 ppm (Typical Short-term Repeatability)
    • 1 Year Stability : As good as 10 ppm
  15. Megger Calibration Set of High Resistance Standards

    VRS-100 Series High Resistance Standards

    • Set of nine, ten or eleven resistors - 1 kΩ, 10 kΩ, 100 kΩ,1 MΩ, 10 MΩ, 100 MΩ, 1 GΩ, 10 GΩ, 100 GΩ, 1 TΩ and 10 TΩ , open circuit (Depending on model)
    • High Accuracy - up to 20 ppm
    • Standard voltage: up to 5 kV (voltages of 10 kV are available)
    • Excellent for Meggers