  1. esi RS925

    esi RS925D Resistance Decade

    • High accuracy - 20 ppm + 0.5 mΩ
    • High stability - 20 ppm + 0.5 mΩ
    • Resistance from 10 mΩ to 1.1 MΩ
    • 20 μΩ resolution 
    • Precise fixed minimum resistance
  2. SR-1050 Transfer Standard

    esi SR1050 Series 1M & 10 M Resistance Transfer Standard

    • Resistance Values 1 MΩ & 10 MΩ
    • Initial Accuracy... ± 25 or 30 ppm of nominal value matched within 10 ppm
    • Transfer Accuracy... ± 2 ppm (Typical Short-term Repeatability)
    • Calibration Accuracy... ± 10 or 15 ppm
  3. Programmable Decade Resistor

    PRS-300 Precision Programmable Resistance Decade

    • Resistance Range: 0.1 Ω to 20 MΩ
    • Precision Lab Grade Accuracy 70 ppm + 1 mΩ Resolution: 1 μΩ ( 0.000 001 Ω)
    • To further improve accuracy to <20 ppm, for no additional cost, see the PRS-DMM
    • Programmable Decade Resistor with USB Interface and Labview Drivers
    • 5 Year Warranty
  4. Resistance Transfer Standard

    esi SR1030 Series Oil Immersed Transfer Standard

    • Resistance Values of 1 Ω - 100 kΩ
    • Initial Accuracy... ± 20 PPM of nominal value matched within 10 PPM
    • Transfer Accuracy... ± (1 PPM + 0.1uΩ at parallel value) for 100:1
    • Long Term Accuracy... ± 50 PPM of nominal value
    • Calibration Accuracy... ± 10 PPM
  5. PRS Rack Model

    PRS Series Programmable Resistance Decade Box

    • IEEE, RS232 or Ethernet Programmable Decade Resistor
    • Wide range and resolution: 1 mΩ to 100 MΩ
    • Available at accuracies of : 0.01%, 0.02%, 0.05%, 0.1%, 0.5%, and 1%
    • Special RTD and custom configurations
    • Dual / Combo rackmount models ( examples: resistance & capacitance )
    • Consider NEW PRS-300 Decade Resistor
  6. Megger Calibration Set of High Resistance Standards

    VRS-100 Series High Resistance Standards

    • Set of nine, ten or eleven resistors - 1 kΩ, 10 kΩ, 100 kΩ,1 MΩ, 10 MΩ, 100 MΩ, 1 GΩ, 10 GΩ, 100 GΩ, 1 TΩ and 10 TΩ , open circuit (Depending on model)
    • High Accuracy - up to 20 ppm
    • Standard voltage: up to 5 kV (voltages of 10 kV are available)
    • Excellent for calibration of Meggers
  7. SR1010 Resistance Transfer Standard

    esi SR1010 Resistance Transfer Standard

    • Resistance Transfer Standards available in the following values 1 Ω, 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ
    • Initial Accuracy... ± 20PPM of nominal value matched within 10PPM
    • Transfer Accuracy... ± (1PPM + 0.1uΩ at parallel value) for 100:1
    • Transfer Accuracy... ± (1PPM + 1uΩ at series parallel value) for 10:1
    • Long Term Accuracy... ± 50PPM of nominal value
    • Calibration Accuracy... ± 10PPM
  8. esi/Tegam DB62 Decade Resistance Box

    esi / Tegam DB62 Decade Resistor

    • Precision accuracy of ±(0.01% + 2 mΩ)
    • Resistance range from 0.01 Ω to 11.1111 MΩ
    • 4 models available, each covering six decades
    • High-performance solid silver-alloy contacts
    • Low zero resistance < 6mΩ
  9. HPRS-Hipot-QuadTech-Load current calibration load resistor

    HPRS-HIPOT-QuadTech Hipot Current Calibration Load Resistors

    • 8 Resistances 0.8 Ω, and from 50 kΩ to 1 GΩ standard
    • Standard accuracy: ±5% at 23°C
    • Power rating : up to 200 W at 50 kΩ
    • Voltage rating: 2,000 V peak except 0.8 Ω
    • Continuous operation at rated power
    • Kel-F washers on all terminals for low leakage current and high dielectric strength
    • Custom Values Available See HPRS-Hipot-Load
  10. HRRS-5-100M-5kV

    HRRS-5 kV & 10 kV Series - High Resistance Decade Box

    • Resistance from 1 Ω to 10 TΩ +
    • High-accuracy: up to .01%; 3 Accuracy Classes
    • Max voltage of 5 kV or 10 kV; 2 Series
    • Ideal for the calibration of meggers
  11. RTD Precision RTD Simulator

    RTD Series - Precision RTD Simulator

    • Highest accuracy, highest stability, lowest TC of any RTD Simulator available
    • Accuracy for Z Series: 0.005% (0.012 ºC for PT 100)
    • Resolution: 1 mΩ (0.0025 ºC for PT 100)
    • Stability 0.0002% for 24 hours; 0.001% for 12 months
    • PT100 to Resistance Chart with 0.1 mΩ Resolution
  12. Fluke 5320A-Load Hipot current calibration load resistor

    HPRS-HIPOT-LOAD (Fluke 5320A-Load Hipot Replacement) Hipot Current Calibration Load Resistors

    • 8 Resistances from 10 kΩ to 5 MΩ standard
    • Standard accuracy: ±10% at 23°C
    • Power rating : up to 300 W at 100 kΩ
    • Voltage rating: 1,400 to 5,500 V depending upon resistance value
    • Continuous operation at rated power
    • Kel-F washers on all terminals for low leakage current and high dielectric strength
    • Custom Values Available
  13. HARS-LX-10-0.001

    HARS-LX Series Decade Resistance Substituter Lab Standard

    • High accuracy - as good as 20 ppm
    • High stability - as good as 5 ppm/yr
    • Over 55 models available with resistance from 1 mΩ to 121.1 MΩ
    • Resolution as good 1 mΩ with a fixed decade or 20 μΩ with a rheostat.
  14. HPRS-F-7-0.001 High Power Decade Resistance Box

    HPRS Series High Power Resistance Decade Box

    • Resistance from 1 mΩ to 10 MΩ
    • Power Rating : 225 W/decade, 250 W max. or higher (Contact IET for Custom Higher Power Units)
    • Accuracy: 0.5% or 1%
    • Special and custom configurations available
  15. OS-270 OhmSOURCE with Leads

    ohmSource Resistance Decade Box / RTD Simulator

    • The revolutionary ohmSOURCE Microprocessor Controlled Resistance Decade Boxes are like nothing you have ever seen before!
    • Two cost-effective models available
    • Accuracy's as tight as 0.01%, with resolution as good as 0.01Ω
    • Engineered as an ideal RTD Calibrator 