Resistance
-
LOM-510A Micro-Ohmmeter
- 1 μΩ resolution, 4½ digits
- Range: 1 μΩ - 200 Ω
- 0.02% basic accuracy
- Costs around 50% less then its peer instruments
- 4-Wire Design to eliminate lead resistance
-
SRL Series Precision Resistance Standard
- Very stable - up to 2 ppm/yr
- Wide range of values - 1 mΩ to 10 TΩ,
- Used by National Measurment Institutes across the world
- 3 Year Warranty Included
-
LOM-530 Micro-Ohmmeter Calibration Kit
- Complete set of (5) working standard resistors for calibration of micro-ohmmeters.
- Resistance values can be custom modified per your requirement.
- Calibrates a wide verity of micro-ohmmeters from various manufacturers
-
esi / Tegam DB62 Decade Resistor
- Precision accuracy of ±(0.01% + 2 mΩ)
- Resistance range from 0.01 Ω to 11.1111 MΩ
- 4 models available, each covering six decades
- High-performance solid silver-alloy contacts
- Low zero resistance < 6mΩ
-
HATS-LR Low Resistance Transfer Standard
- Values from 1 Ω - 100 kΩ
- Initial Accuracy... As good as 10 ppm of nominal value
- Transfer Accuracy... ± (1 ppm + 0.1uΩ at parallel value) for 10:1 & 100:1 ratios
- Long Term Accuracy... ± 10 ppm/year
- Calibration Accuracy... ± 5 ppm
-
esi SR1010 Resistance Transfer Standard
- Resistance Transfer Standards available in the following values 1 Ω, 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ
- Initial Accuracy... ± 20PPM of nominal value matched within 10PPM
- Transfer Accuracy... ± (1PPM + 0.1uΩ at parallel value) for 100:1
- Transfer Accuracy... ± (1PPM + 1uΩ at series parallel value) for 10:1
- Long Term Accuracy... ± 50PPM of nominal value
- Calibration Accuracy... ± 10PPM
-
HATS-Y Series High Resistance Transfer Standard
- Resistance Values 100 kΩ, 1 MΩ, 10 MΩ, 100 MΩ
- Initial Accuracy...As good as 10 ppm nominal value matched within 10 ppm
- Transfer Accuracy... ± 2 ppm (Typical Short-term Repeatability)
- 1 Year Stability : As good as 10 ppm
-
VRS-100 Series High Resistance Standards
- Set of nine, ten or eleven resistors - 1 kΩ, 10 kΩ, 100 kΩ,1 MΩ, 10 MΩ, 100 MΩ, 1 GΩ, 10 GΩ, 100 GΩ, 1 TΩ and 10 TΩ , open circuit (Depending on model)
- High Accuracy - up to 20 ppm
- Standard voltage: up to 5 kV (voltages of 10 kV are available)
- Excellent for Meggers
-
esi SR1030 Series Oil Immersed Transfer Standard
- Resistance Values of 1 Ω - 100 kΩ
- Initial Accuracy... ± 20 PPM of nominal value matched within 10 PPM
- Transfer Accuracy... ± (1 PPM + 0.1uΩ at parallel value) for 100:1
- Long Term Accuracy... ± 50 PPM of nominal value
- Calibration Accuracy... ± 10 PPM
-
SRR Series Precision Low Reichanstalt Type Standard Resistor
- Reichanstalt Type four-terminal resistors
- Resistance Value of: 0.0001 Ω, 0.001 Ω, 0.01 Ω, 0.1 Ω
-
PRS Series Programmable Resistance Decade Box
- IEEE or RS232 Programmable Decade Resistor
- Wide range and resolution: 1 mΩ to 100 MΩ
- Available at accuracies of : 0.01%, 0.02%, 0.05%, 0.1%, 0.5%, and 1%
- Special RTD and custom configurations
- Dual / Combo rackmount models ( examples: resistance & capacitance )
-
GenRad 1863 Megohmmeter
- Rugged and Portable Analog Megohmmeter
- Up to 3% Accuracy
- 5 Test Voltages from 50, 100, 200, 250, 500 VDC
- 50 kΩ to 20 TΩ Measurement Range
- Maximum of 5 mA Charge Current
- Analog Output
-
GenRad 1864 Megohmmeter
- 200 Test Voltages from 10 V to 1090 VDC
- Rugged and Portable Analog Megohmmeter
- Up to 3% Accuracy
- 50 kΩ to 200 TΩ Measurement Range
- Reliable High Quality Instrument Designed to Last up to 30 years
-
1865+ Digital Megohmmeter I/R Tester
- Measurements from 1kΩ to 100TΩ, with Auto Ranging
- 0.5% measurement accuracy
- Improved High-visibility blue LCD graphical display for Menu Programming and Test Results
- Programmable Test Voltage from 1 to 1000VDC
- Fully Programmable Measure Cycle Times
- Automatic Test Lead Zeroing To Eliminate Connection Errors
- Direct Reading of Measured Resistance or Current
-
esi SR1050 Series 1M & 10 M Resistance Transfer Standard
- Resistance Values 1 MΩ & 10 MΩ
- Initial Accuracy... ± 25 or 30 ppm of nominal value matched within 10 ppm
- Transfer Accuracy... ± 2 ppm (Typical Short-term Repeatability)
- Calibration Accuracy... ± 10 or 15 ppm