Decade Resistor

Resistance Substituters

IET Labs manufactures a full line of resistance decade boxes that will meet any application. Our resistance decade boxes can be custom built to your specifications, so you do not have to pay for what you don't need.
IET Labs, maintains some of the finest R, L and C calibration standards in the World. IET Labs continues to manufacture and support a wide variety of products that were originally manufactured by GenRad, esi, QuadTech and others. The majority of IET’s products are manufactured with pride in the USA.

1433 Series Precision Decade Resistance Box
Find out more about our different decade box models

6 Item(s)

per page

Set Descending Direction
  1. HARS-LX-10-0.001

    HARS-LX Series Decade Resistance Substituter Lab Standard

    • High accuracy - as good as 20 ppm
    • High stability - as good as 5 ppm/yr
    • Over 55 models available with resistance from 1 mΩ to 121.1 MΩ
    • Resolution as good 1 mΩ with a fixed decade or 20 μΩ with a rheostat.
  2. RTD Precision RTD Simulator

    RTD Series - Precision RTD Simulator

    • Highest accuracy, highest stability, lowest TC of any RTD Simulator available
    • Accuracy for Z Series: 0.005% (0.012 ºC for PT 100)
    • Resolution: 1 mΩ (0.0025 ºC for PT 100)
    • Stability 0.0002% for 24 hours; 0.001% for 12 months
    • PT100 to Resistance Chart with 0.1 mΩ Resolution
  3. Resistance Transfer Standard

    esi SR1030 Series Oil Immersed Transfer Standard

    • Resistance Values of 1 Ω - 100 kΩ
    • Initial Accuracy... ± 20 PPM of nominal value matched within 10 PPM
    • Transfer Accuracy... ± (1 PPM + 0.1uΩ at parallel value) for 100:1
    • Long Term Accuracy... ± 50 PPM of nominal value
    • Calibration Accuracy... ± 10 PPM
  4. SR1010 Resistance Transfer Standard

    esi SR1010 Resistance Transfer Standard

    • Resistance Transfer Standards available in the following values 1 Ω, 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ
    • Initial Accuracy... ± 20PPM of nominal value matched within 10PPM
    • Transfer Accuracy... ± (1PPM + 0.1uΩ at parallel value) for 100:1
    • Transfer Accuracy... ± (1PPM + 1uΩ at series parallel value) for 10:1
    • Long Term Accuracy... ± 50PPM of nominal value
    • Calibration Accuracy... ± 10PPM
  5. SR-1050 Transfer Standard

    esi SR1050 Series 1M & 10 M Resistance Transfer Standard

    • Resistance Values 1 MΩ & 10 MΩ
    • Initial Accuracy... ± 25 or 30 ppm of nominal value matched within 10 ppm
    • Transfer Accuracy... ± 2 ppm (Typical Short-term Repeatability)
    • Calibration Accuracy... ± 10 or 15 ppm
  6. esi RS925

    esi RS925D Resistance Decade

    • High accuracy - 20 ppm + 0.5 mΩ
    • High stability - 20 ppm + 0.5 mΩ
    • Resistance from 10 mΩ to 1.1 MΩ
    • 20 μΩ resolution 
    • Precise fixed minimum resistance