Resistance Standard
-
SR102/103/104 Series
- Highest accuracy (1 ppm/yr) and stability (±0.5 ppm/yr typical) of any resistance standard
- Lowest temperature coefficients (< 0.1 ppm/ºC)
- Available in 3 models: 100Ω, 1000 Ω, 10,000Ω.
- Has remained the foremost resistance standard, with no equivalent, for over 35 years
- 5 Year Warranty Included
-
SRX1 Series NAVAIR Resistance Standard
- Range from 1 Ω - 1 MΩ
- Stabilities as good as 5 ppm
- Minimal Change from power cycling
- The US Navy's Resistance Standard
-
HARS-LX Series Decade Resistance Substituter Lab Standard
- High accuracy - as good as 20 ppm
- High stability - as good as 5 ppm/yr
- Over 55 models available with resistance from 1 mΩ to 121.1 MΩ
- Resolution as good 1 mΩ with a fixed decade or 20 μΩ with a rheostat.
-
HATS-LR Low Resistance Transfer Standard
- Values from 1 Ω - 100 kΩ
- Initial Accuracy... As good as 10 ppm of nominal value
- Transfer Accuracy... ± (1 ppm + 0.1uΩ at parallel value) for 10:1 & 100:1 ratios
- Long Term Accuracy... ± 10 ppm/year
- Calibration Accuracy... ± 5 ppm
-
esi SR1010 Resistance Transfer Standard
- Resistance Transfer Standards available in the following values 1 Ω, 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ
- Initial Accuracy... ± 20PPM of nominal value matched within 10PPM
- Transfer Accuracy... ± (1PPM + 0.1uΩ at parallel value) for 100:1
- Transfer Accuracy... ± (1PPM + 1uΩ at series parallel value) for 10:1
- Long Term Accuracy... ± 50PPM of nominal value
- Calibration Accuracy... ± 10PPM
-
esi SR1030 Series Oil Immersed Transfer Standard
- Resistance Values of 1 Ω - 100 kΩ
- Initial Accuracy... ± 20 PPM of nominal value matched within 10 PPM
- Transfer Accuracy... ± (1 PPM + 0.1uΩ at parallel value) for 100:1
- Long Term Accuracy... ± 50 PPM of nominal value
- Calibration Accuracy... ± 10 PPM
-
HATS-Y Series High Resistance Transfer Standard
- Resistance Values 100 kΩ, 1 MΩ, 10 MΩ, 100 MΩ
- Initial Accuracy...As good as 10 ppm nominal value matched within 10 ppm
- Transfer Accuracy... ± 2 ppm (Typical Short-term Repeatability)
- 1 Year Stability : As good as 10 ppm
-
esi SR1050 Series 1M & 10 M Resistance Transfer Standard
- Resistance Values 1 MΩ & 10 MΩ
- Initial Accuracy... ± 25 or 30 ppm of nominal value matched within 10 ppm
- Transfer Accuracy... ± 2 ppm (Typical Short-term Repeatability)
- Calibration Accuracy... ± 10 or 15 ppm
-
esi SR1 Standard Resistor
- New Design, With Improved Specifications
- Versatile working standard
- Laboratory standard of high accuracy and stability
- Adjusted to within 20 ppm of nominal
- 50 ppm long-term accuracy for most values