IET Labs manufactures the highest performing impedance bridges and meters. IET manufactures, repairs, supports and calibrates: the GenRad Digibridge line of LCR meters including the 1689 and 1693, the GR 1621, 1620 Capacitance Meters, and QuadTech 1910, 1920, 7400, 7600 and 7600 Plus Precision LCR Meters. In addition IET also offers the multifunctional, full featured, yet economical DE-6000 LCR meter.

IET Labs is also an A2LA Accredited Calibration Laboratory #2073.01 and can provide ISO-17025 calibration with uncertainties for capacitance, resistance and inductance on GenRad, QuadTech and IET LCR meters as well as the Agilent E4980, HP 4284 and 4263B LCR meters.
Impedance Meters & Bridges

Let us know what your impedance bridges and meters requirement are and we will find you a solution.

Items 1 to 15 of 19 total

per page
Page:
  1. 1
  2. 2

Set Ascending Direction
  1. 1689-9611 Rack Mount Shelf

    1689-9611 Rack Mount Kit for 1689-M/1693

    • Allows both the 1689M and the 1693 digibridges to be rackmounted
  2. 1657-9600

    1657-9600 Banana Plug Extender cable

    • Banana plugs alligator clip extender cable for the 1659, 1689-9700, 1692 digibridges
  3. 1689-9604 Calibration Kit

    1689-9604 Digibridge Calibration Kit

    • Calibration kit for 1659, 1689, 1692 and 1693 digibridges
  4. 1689-9600 Remote Test Fixture

    1689-9600 Remote Test Fixture

    • Test fixture which adapts 1689M & 1693 Digibridges to radial or axial leaded components
    • Allows the 1689M and 1693 to be used with the Digibridge calibration kit
  5. igibridge IEEE Board

    1689-9640 IEEE Digibridge Interface

    • Brand new IEEE-488.2 for the 1659, 1692, 1689, 1693
    • Major upgrade to the older 1658-9620 IEEE-488.1 board
    • Is able to download software updates as they come available from the field via an RS232 port
  6. 7000-04 Alligator Clip Leads, 1 Meter

    7000-04 Alligator Clip Leads, 1 Meter

    • Alligator Clip lead set with 4 BNC to 4 banana plugs and 4 alligator clips.
    • These leads are specifically designed to work with the 1689/89M, 1693, 7600 Plus, 1910, and 1920 LCR Meters
  7. 1700-03 Kelvin Test Leads

    1700-03 Kelvin Test Leads

    • Kelvin clip lead set to 4 BNC’s (30 inches in length)
    • For use with 1689/89M, 1693, 7600 Plus, 1910, and 1920 LCR Meters
    • Use with 1689-9601 BNC Adaptor Box for Digibridges with built-in test fixture
  8. 1620 Capacitance Measuring System

    GenRad 1620 Capacitance Bridge

    • 10-5pF to 11.1 µF, 2-or 3-terminal
    • frequency range 20 Hz -20 kHz (or higher)
    • 0.01% accuracy, 1-ppm resolution
    • reads dissipation factor or conductance
    • combines GenRad 1615 Capacitance Bridge, 1232-A Null Detector & 1311-A Oscillator
  9. IET 1621 Precision Capacitance Bridge

    GenRad 1621 Capacitance Bridge

    • Range 10-7 pF to 10 µF, 12-digit readout
    • 10-ppm basic accuracy
    • frequency range 10 Hz - 100 kHz
    • combines GenRad 1616 Capacitance Bridge, 1238-A Null Detector & 1316 Oscillator
  10. GenRad 1659 Digibridge

    GenRad 1659 Digibridge

    • 0.1% Measurement Accuracy
    • 4 Test Frequencies 100Hz to 10kHz
    • 5 Impedance Parameters
    • Built-in Test Fixture
  11. 1692 Benchtop LCR Meter

    GenRad 1692 Benchtop LCR Meter

    • 0.05% Measurement Accuracy
    • 5 Test Frequencies 100Hz to 100kHz
    • 5 Impedance Parameters
    • Built-in Test Fixture