IET Labs, Inc. - In the GenRad Tradition

Click Here to Contact Us
 



A2LA Accredited
Expanded Scope Now Includes
ac Resistance
(View Certificate)

ISO 9001 Compliant
ANSI/NCSL Z540 Compliant

In the
GenRad
Tradition...
In the GenRad Tradition
The World Leader in Metrology since 1915



Proudly Made in
the USA

SR1010 Transfer Standards - Low Resistance


esi SR1010 Transfer Standardesi / Tegam SR1010 Transfer Standards

  • Initial Accuracy... ± 20PPM of nominal value matched within 10PPM
  • Transfer Accuracy... ± (1PPM + 0.1u at parallel value) for 100:1
  • Transfer Accuracy... ± (1PPM + 1u at series parallel value) for 10:1
  • Long Term Accuracy... ± 50PPM of nominal value
  • Calibration Accuracy... ± 10PPM

For high resistance transfer standards, consider the esi SR1050

esi SR1010 Transfer Standards Datasheet and Full Specifications

IET continues to produce the SR1010 to the same exacting specs as esi/Tegam
esi SR1010
Introduction
The esi SR1010 transfer standards consist of 12 equal resistance steps. These steps are available in increments of 1 (SR1010-1), 10 (SR1010-10), 100 (SR1010-100), 1k (SR1010-1k), 10k (SR1010-10k) and 100k (SR1010-100k). The esi SR1010 provides four-terminal connections for each step or for series and parallel combinations of these resistance steps using the optional Series-Parallel (SPC102), Parallel Compensation Networks (PC101) and shorting bars (SB103). This improves power dissipation, stability and errors due to variance in temperature.

Description
The SR1010 meets or exceeds all of the requirements for resistance transfer standards in precision measurement applications. It is easily configured to transfer resistances up or down a decade from their initial resistance value. When used with the connecting networks and shorting bars, it provides 1 ppm transfer accuracies.

Each transfer standard contains twelve equal value precision resistors connected in series by specially designed true 4-terminal junctions. These special junctions assure that a 4-terminal measurement of a series of resistors agrees with the sums of the individual resistors in the series. Accurate parallel connections can be made with the Parallel Compensation Network and the Shorting Bars connected to the junctions.

These standards can be connected to provide three decade values: 10 resistors in series, 10R: 9 resistors in series — parallel, 1R: and 10 resistors in parallel, R/10. The part per million accuracy is assured as the series value is equal to 100 times the parallel value to better than 1 ppm. The series — parallel value relative to either the series value or the parallel value can be found to better than 1 ppm by making a 1:1 comparison with the remaining tenth resistor and a simple calculation.

The accuracy and precision of the individual resistors also make the esiSR1010 transfer standards ideal for use as amulti-value standard resistor or reference voltage divider.

Advantages of Transfer Standards
In order to perform calibrations with a high degree of accuracy, reference standards must be employed at every range or decade of the measuring or calibration instrumentation. Clearly, this can be difficult and costly since these standards must be highly stable and their precise values must be known with a high degree of certainty and sufficient resolution.

To minimize the cost and difficulty, more practical means of performing such calibrations is to use transfer standards.

If one has a single standard that is calibrated by a national laboratory, one can then compare the transfer standards to the certified standard by ratio techniques. See our Technical Applications section for a full tutorial.
The Benefits of Using Transfer Standards

Accessories
PC-101 Parallel Compensation Network for esi SR1010 & esi SR1030
SB103 Shorting Bars for esi SR1010 & SR1030
SPC102 Series-Parallel Compensation Network for esi SR1010 & esi SR1030


Models
SR1010-1 ---------1 Resistance Transfer Standard
SR1010-10 -------10 Resistance Transfer Standard
SR1010-100 -----100 Resistance Transfer Standard
SR1010-1K -------1 k Resistance Transfer Standard
SR1010-10K -----10 k Resistance Transfer Standard
SR1010-100K ---100 k Resistance Transfer Standard


Google Translate to: