  1. Decade Resistor 9 Dial

    GenRad 1433 Series Decade Resistor

    • Precision accuracy of +0.01%
    • Resistance range from 1 mΩ to 111.11111111 MΩ
    • 36 models available, 3 to 11 dials
    • Long life switches with solid silver contacts
  2. GenRad 1531 Stroboscope

    GenRad 1531-AB Stroboscope

    • High flashing rates up to 25,000 per minute — speed measurements to 250.000 rpm.
    • Short flash duration — "stops" rapid motion and permits ultra-high-speed photography.
    • High accuracy stroboscope — rpm measurements can be made to ± 1%.
  3. GenRad 1538-A Stroboscope

    GenRad 1538-A Stroboscope

    • The highest flashing rates for a stroboscope-up to 150,000 Flashes per mn,
    • Flash duration from 0.5 μs to 3.0 μs for clear, crisp images.
    • Accessory energy-storage capacitor 1538-P4 for very short single flashes.
    • High accuracy stroboscope — rpm measurements can be made to ± 1%
  4. GenRad 1542 Stroboscope

    GenRad 1542 Stroboscope

    • Low-cost, excellent US Manufactured stroboscope for stopping motion
    • Up to 3800 bright-white flashes per minute -to observe motion as fast as 40,000 rpm
    • Simple push-button operation
    • Compact, light-weight, rugged
  5. GenRad 1546 Digital Stroboscope

    GenRad 1546 Digital Stroboscope

    • High flashing rates for a stroboscope-up to 25,000 Fashes per minute, direct reading.
    • Flash duration from 1.2 μs to 2 μs for clear, crisp images.
    • Lightweight and handheld, very easy to use unit with digital readout
  6. Externally Triggered

    GenRad 1539-A Externally Triggered Stroboscope

    • Small size and light weight.
    • Light source on flexible cable for convenient positioning.
    • Can be triggered by several methods.
    • For machine maintenance, Real time inspection of moving parts, Printing press applications, Motor troubleshooting, For stopping motion
  7. Sound Level Calibrator

    GenRad 1562-A Sound Level Calibrator

    • Workhorse of the acoustics field
    • Calibrates most sound-level meters
    • Generates standard levels and frequencies
    • Adaptable to various microphone sizes
    • Use in the lab or in the field
  8. 1840-A Output Power Meter

    GenRad 1840-A Output Power Meter

    • Power output of oscillators, amplifiers, preamplifiers, transformers, transducers, and low-frequency lines.
    • Output impedance, by adjustment of the load to yield maximum power indication.
    • Frequency-response characteristics of amplifiers, transformers, and other audio-frequency devices.
  9. 1455 Series Decade Voltage Divider

    1455 Series Decade Voltage Divider

    • Linearity better than 20 ppm (5-dial model) 
    • Input impedance: for 1455-A 10 kΩ & 1455-B, 1455-BH 100 kΩ 
    • High-frequency model, down 3 dB at 7.5 MHz
  10. 1482 Inductance Standard

    GenRad 1482 Series Inductance Standard

    • Stable within ±0.01% per year
    • 18 Models values from 1 µH to 10 H
    • Low, known temperature coefficient
    • 3 year warranty included
  11. GenRad 1409 Series Standard Capacitor

    GenRad 1409 Series Standard Capacitor

    • Values 0.001 µF (100 nF)  to 1000 µF
    • Stability as good as ±0.01 %/year
    • Two-to-five terminal configuration, depending on model
    • Calibration accredited to ISO-17025 included
    • 3 year warranty included
  12. Sound Level Meter

    GenRad 1565-B Sound-Level Meter

    • 40 to 140 dB
    • ANSI Type 2 A, B, C weighting
    • Fast/slow meter response
    • MESA approved
    • Convenient pocket proportions -small and light
  13. 1689-9700 Precision Impedance Meter

    GenRad 1689 Precision Impedance Meter

    • The world's standard for AC Resistance, Low Frequency Inductance and Capacitance measurement
    • 0.02% Measurement Accuracy and +/- 0.0001 Df
    • Programmable Frequency 12 Hz - 100 kHz
    • Widely accepted impedance meter in a metrology environment
    • 1689 has a built-in 4 terminal kelvin fixture for testing axial and radial components
    • 1689M has four BNC connectors for use with a wide variety of standard accessories
  14. GenRad 1659 Digibridge

    GenRad 1659 Digibridge

    • 0.1% Measurement Accuracy
    • 4 Test Frequencies 100Hz to 10kHz
    • 5 Impedance Parameters
    • Built-in Test Fixture
  15. 1692 Benchtop LCR Meter

    GenRad 1692 Benchtop LCR Meter

    • 0.05% Measurement Accuracy
    • 5 Test Frequencies 100Hz to 100kHz
    • 5 Impedance Parameters
    • Built-in Test Fixture

Items 1 to 15 of 28 total