GenRad

Items 1 to 15 of 28 total

per page
Page:
  1. 1
  2. 2

Set Descending Direction
  1. Decade Resistor 9 Dial

    GenRad 1433 Series Decade Resistor

    • Precision accuracy of +0.01%
    • Resistance range from 1 mΩ to 111.11111111 MΩ
    • 36 models available, 3 to 11 dials
    • Dust proof, long life switches with solid silver contacts
    • Excellent frequency characteristics
  2. GenRad 1404 Series Primary Standard Capacitors

    GenRad 1404 Series Primary Standard Capacitors

    • A national laboratory standard
    • Available in 10 pF, 100 pF,1000 pF, 10,000 pF
    • 20 ppm/year stability, history has shown this to be a very conservative specification
    • Hermetically sealed in dry nitrogen
    • 5 Year Warranty Included 

  3. High Frequency Standard Capacitor

    GenRad 1403 Series High Frequency Standard Capacitor

    • Available in values from 0.001 pF - 1000 pF
    • Excellent Performance at high frequencies
    • ISO-17025 Accredited Calibration Included with the Standard
  4. Decade Capacitor

    Genrad 1413 Precision Decade Capacitor

    • Range from 1 pF to 1.11111 µF
    • High accuracy of 0.05% + 0.5 pF
    • Excellent Stability 100 ppm per year
    • The trusted lab standard for capacitance
    • 3-Terminal shielded construction
  5. GenRad 1412-BC Decade Capacitance Box

    GenRad 1412-BC Decade Capacitance Box

    • Range from 50 pF to 1.11115 µF
    • Resolution better then 1 pF
    • Accuracy 0.5% + 5 pF
    • Low loss, leakage, dielectric absorption
    • Verification of calibration of LCR meters, multimeters, and instrumentation
  6. GenRad 1419 Series Decade Capacitor

    GenRad 1419 Series Decade Capacitor

    • Range from 100 pF to 1.1 µF
    • Choice of 3 models
    • Accuracy as good as 0.5%
    • Capacitance and dissipation factor vary only slightly with frequency from dc through the audio frequency range.
  7. GenRad 1417 Capacitance Standard  1 uF - 1 F

    GenRad 1417 Capacitance Standard 1 uF - 1 F

    • 7 Switch-Selected Standard Capacitance Values: 1 µF , 10 µF , 100 µF , 1 mF , 10 mF ,100 mF , 1 F
    • 3 Switch-Selected Test Frequencies: 100 Hz, 120 Hz, 1 kHz
    • 0.25% direct-reading capacitance accuracy
    • 0.1% or better ratio accuracy
  8. GenRad 1422 Air Capacitor

    GenRad 1422 Series Variable Air Capacitors

    • Range as low as 0.002 pF and as high as 1150 pF (Depending on Model)
    • Stability: better than 0.02% full scale per year
    • Settable to 40 ppm
    • Low temperature coefficient, low losses
    • Wide selection to suit needs
  9. GenRad 1423-A Decade Capacitor

    GenRad 1423-A Decade Capacitor

    • Range 100pF - 1.111 µF
    • ±0.05% accuracy
    • two- or three-terminal connection
  10. GenRad 1491 D, G Precision Decade Inductor

    GenRad 1491 D, G Precision Decade Inductor

    • Most accurate decade inductor commercially available, accuracy's as good as 0.8%
    • Inductance range from 1 mH or 100 µH to 11 H
    • Shielded toroidal cores for small mutual inductance and minimal effect from external fields
    • Sealed against moisture for long-term stability
  11. GenRad 1863 Megohmmeter

    GenRad 1863 Megohmmeter

    • 5 Test Voltages from 50, 100, 200, 250, 500 VDC
    • Rugged and Portable Analog Megohmmeter
    • Up to 3% Accuracy
    • Suggested Equipment in Boeing Service Bulletins for DC-10, 747 and others
    • Reliable High Quality Instrument Designed to Last up to 30 years
  12. Megohmmeter

    GenRad 1864 Megohmmeter

    • 200 Test Voltages from 10 V to 1090 VDC
    • Rugged and Portable Analog Megohmmeter
    • Up to 3% Accuracy
    • 50 kΩ to 200 TΩ Measurement Range
    • Reliable High Quality Instrument Designed to Last up to 30 years
  13. Impedance Bridge

    GenRad 1693 Precision Impedance Bridge

    • The world's standard for AC Resistance, Low Frequency Inductance and Capacitance 
    • 0.02% Measurement Accuracy  Programmable Frequency 12 Hz - 200 kHz
    • Extremely Reliable can last up to 30+ years
    • 11 Impedance Parameters
  14. 1692 Benchtop LCR Meter

    GenRad 1692 Benchtop LCR Meter

    • 0.05% Measurement Accuracy
    • 5 Test Frequencies 100Hz to 100kHz
    • 5 Impedance Parameters
    • Built-in Test Fixture
  15. GenRad 1659 Digibridge

    GenRad 1659 Digibridge

    • 0.1% Measurement Accuracy
    • Cost-Effective Solution
    • 4 Test Frequencies 100Hz to 10kHz
    • 5 Impedance Parameters
    • Built-in Test Fixture

Items 1 to 15 of 28 total

per page
Page:
  1. 1
  2. 2

Set Descending Direction