HRRS-B-5-10K-5KV High Resistance Decade Box

- Resistance from 10 Ω to 100 GΩ
- High-accuracy: up to .01%, 3 Accuracy Classes Available
- Voltage up to 2000 V
- Excellent TC: as low as 5 ppm/°C
- Low voltage coefficient: as low as 0.2 ppm/V
Estimated Delivery is 4 to 6 weeks
Repair/Calibration Quote Technical Support Request- Resistance from 10 Ω to 100 GΩ
- High-accuracy: up to .01%, 3 Accuracy Classes Available
- Voltage up to 2000 V
- Excellent TC: as low as 5 ppm/°C
- Low voltage coefficient: as low as 0.2 ppm/V
- High-performance solid silver-alloy switches
- Rack mounting available
The High Resistance (HRRS Series) is an economical, high-performance, high-resistance decade box for all laboratory, test, and calibration needs. The High-resistance design is implemented with special resistors, switches, binding posts, and construction-design to allow high resistance performance without sacrificing other electrical properties. These instruments are useful wherever small currents and high resistances are required,
The HRRS Series employs state-of-the-art precision resistors of various types for high accuracy, high stability, and low temperature and voltage coefficients. The standard models offer a choice of one to seven decades. For custom units, models up to 11 decades are available . For higher voltage or higher resistance, models up to >10 kV and 10 TΩ are also available in the HRRS-5kV & -10kV Series.
The binding posts are for the HRRS high resistance decade boxes are insulated with Kel-F high-resistance, non-moisture-absorbing material ensure low leakage.
With a resolution as low as 10 Ω and a maximum available resistance of over 100 G&Omega, the HRRS Series may be used for exacting precision high-value resistance applications.
The HRRS series decade box complements the HARS series which provides resistance steps as low as 1 mΩ. The units may be rack-mounted to serve as components in measurement and control systems.
HRRS High Resistance Decade Box Applications
- calibration of meters and megohmmeters,
- checking of electrochemical and biomedical sensors and instruments.
- testing high-impedance amplifiers and the insulation of low-power circuits.
HRRS Basic Specifications
|
Resistance per step
|
Total decade resistance
|
Accuracy
|
Max voltage per step (V)
|
Maximum Voltage (V)
|
Temperature coefficient (ppm/C)
|
Voltage coefficient (ppm/V)
|
Stability (ppm/yr)
|
Resistor Type
|
||
|
Q
|
B
|
F
|
||||||||
| 10Ω | 100Ω | 0.01% | 0.03% | 0.10% | 2.5 | 25 | 15 | 0 | 10 | Wirewound, non-inductive |
| 100Ω | 1kΩ | 0.01% | 0.03% | 0.10% | 8 | 80 | 5 | 0 | 10 | Wirewound, non-inductive |
| 1kΩ | 10kΩ | 0.01% | 0.03% | 0.10% | 23 | 230 | 5 | 0 | 10 | Wirewound, non-inductive |
| 10kΩ | 100kΩ | 0.01% | 0.03% | 0.10% | 70 | 700 | 5 | 0 | 10 | Wirewound, non-inductive |
| 100kΩ | 1MΩ | 0.01% | 0.03% | 0.10% | 230 | 2000 | 5 | 0 | 10 | Wirewound, non-inductive |
| 1MΩ | 10MΩ | 0.01% | 0.03% | 0.10% | 1000* | 2000 | 15 | 0.2 | 25 | Metal-oxide film |
| 10MΩ | 100MΩ | 0.03% | 0.10% | 1% | 1000* | 2000 | 15 | 0.2 | 50 | Metal-oxide film |
| 100MΩ | 1GΩ | 0.10% | 0.20% | 1% | 1000* | 2000 | 15 | 1.5 | 100 | Metal-oxide film |
| 1GΩ | 10GΩ | 0.20% | 0.50% | 1% | 1000* | 2000 | 50 | 5 | 500 | High-voltage film |
| 10GΩ | 100GΩ | 0.50% | 1% | 1% | 1000* | 2000 | 50 | 5 | 500 | High-voltage film |
| 100GΩ | 1TΩ | 0.50% | 1% | 1% | 1000* | 2000 | 100 | 5 | 500 | High-voltage film |
-

NIST Traceable Calibration Cert (Included)
+ $0.00
-

ISO-17025 Accredited Calibration with Test Data
+ $150.00
-

Rackmount Kit
+ $179.00
-

Rear output binding posts
+ $59.00
-

Kelvin type 4-terminal binding post
+ $289.00
-

Handles
+ $99.00
Product Categories
-
http://www.ietlabs.com/decaderes.htmlResistance
-
http://www.ietlabs.com/decaderes/decade-resistor.htmlDecade Resistor
-
http://www.ietlabs.com/decaderes/resistance-standard.htmlResistance Standard
-
http://www.ietlabs.com/decaderes/resistance-meter.htmlOhmmeter
-
-
http://www.ietlabs.com/capacitance.htmlCapacitance
-
http://www.ietlabs.com/capacitance/decade-capacitor.htmlDecade Capacitor
-
http://www.ietlabs.com/capacitance/capacitance-standard.htmlCapacitance Standard
-
http://www.ietlabs.com/capacitance/capacitance-meter-bridge.htmlCapacitance Bridges
-
-
http://www.ietlabs.com/inductance.htmlInductance
-
http://www.ietlabs.com/inductance/decade-inductor.htmlDecade Inductor
-
http://www.ietlabs.com/inductance/inductance-standard.htmlInductance Standard
-
http://www.ietlabs.com/inductance/inductance-meter.htmlInductance Meter
-
-
http://www.ietlabs.com/decadebox.htmlDecade Boxes
-
http://www.ietlabs.com/rtds.htmlRTD Simulators
-
http://www.ietlabs.com/micro-ohmmeter.htmlMicro-Ohmmeters
-
http://www.ietlabs.com/ohmmeters.htmlMegohmmeters
-
http://www.ietlabs.com/digibridges.htmlImpedance Meters & Bridges
-
http://www.ietlabs.com/lcr-meter.htmlLCR Meter
-
http://www.ietlabs.com/variac.htmlVariacs
-
http://www.ietlabs.com/stroboscope.htmlStroboscopes
-
http://www.ietlabs.com/sound-level-meter.htmlAudio
-
http://www.ietlabs.com/voltage-divider.htmlVoltage Dividers
-
http://www.ietlabs.com/decadevi.htmlVoltage & Current Sources
-
http://www.ietlabs.com/gr874-connectors.htmlGR 874 / Test Leads
-
http://www.ietlabs.com/dielectric-cells.htmlDielectric Test Cells
-
http://www.ietlabs.com/scrollingcatalog.htmlScrolling Catalog
- Home
- Products
- Calibration & Repair
- Company
- Contact Us
- Terms/Privacy Policy
- Request Quote
- Technical Support
- Site Map
PHONE: (516) 334-5959 FAX: (516) 334-5988 SALES@IETLABS.COM