GenRad 1409 Series Standard Capacitor
- Values 0.001 µF (100 nF) to 1000 µF
- Stability as good as ±0.01 %/year
- Two-to-five terminal configuration, depending on model
- Calibration accredited to ISO-17025 included
- 3 year warranty included
SCA Series Capacitance Standard
- Values from 1 pF to 10,000 µF in any custom value available
- Stability as good as ±0.01 %/year
- Two-to-five terminal configuration, depending on model
- Excellent TC: as low as 10 ppm/°C
- 3 year warranty included
GenRad 1404 Series Primary Standard Capacitors
- A national laboratory standard
- For calibrating working standards
- Standard for dissipation factor
- Available in 10 pF, 100 pF,1000 pF, 10,000 pF
- 5 Year Warranty Included
HARS-LX Series Decade Resistance Substituter Lab Standard
- High accuracy - as good as 20 ppm
- High stability - as good as 5 ppm/yr
- Over 55 models available with resistance from 1 mΩ to 121.1 MΩ
- Resolution as good 1 mΩ with a fixed decade or 20 μΩ with a rheostat.
GenRad 1403 Series High Frequency Standard Capacitor
- Available in values from 0.001 pF - 1000 pF
- Excellent Performance at high frequencies
- ISO-17025 Accredited Calibration Included with the Standard
esi RS925D Resistance Decade
- High accuracy - 20 ppm + 0.5 mΩ
- High stability - 20 ppm + 0.5 mΩ
- Resistance from 10 mΩ to 1.1 MΩ
- 20 μΩ resolution
- Precise fixed minimum resistance
HATS-LR Low Resistance Transfer Standard
- Values from 1 Ω - 100 kΩ
- Initial Accuracy... As good as 10 ppm of nominal value
- Transfer Accuracy... ± (1 ppm + 0.1uΩ at parallel value) for 10:1 & 100:1 ratios
- Long Term Accuracy... ± 10 ppm/year
- Calibration Accuracy... ± 5 ppm
HATS-Y Series High Resistance Transfer Standard
- Resistance Values 100 kΩ, 1 MΩ, 10 MΩ, 100 MΩ
- Initial Accuracy...As good as 10 ppm nominal value matched within 10 ppm
- Transfer Accuracy... ± 2 ppm (Typical Short-term Repeatability)
- 1 Year Stability : As good as 10 ppm
LOM-530 Micro-Ohmmeter Calibration Kit
- Complete set of (5) working standard resistors for calibration of micro-ohmmeters.
- Resistance values can be custom modified per your requirement.
- Calibrates a wide verity of micro-ohmmeters from various manufacturers
VRS-100 Series High Resistance Standards
- Set of nine, ten or eleven resistors - 1 kΩ, 10 kΩ, 100 kΩ,1 MΩ, 10 MΩ, 100 MΩ, 1 GΩ, 10 GΩ, 100 GΩ, 1 TΩ and 10 TΩ , open circuit (Depending on model)
- High Accuracy - up to 20 ppm
- Standard voltage: up to 5 kV (voltages of 10 kV are available)
- Excellent for Meggers
RTD Series - Precision RTD Simulator
- Highest accuracy, highest stability, lowest TC of any RTD Simulator available
- Accuracy for Z Series: 0.005% (0.012 ºC for PT 100)
- Resolution: 1 mΩ (0.0025 ºC for PT 100)
- Stability 0.0002% for 24 hours; 0.0001% for 12 months
esi SR1 Standard Resistor
- New Design, With Improved Specifications
- Versatile working standard
- Laboratory standard of high accuracy and stability
- Adjusted to within 20 ppm of nominal
- 50 ppm long-term accuracy for most values
DCCS DC Current Shunt Series
- Allows for High Current Calibration, up to 60 A
- Resistances ranges from 100 µΩ - 1 kΩ
- High Accuracy 0.02%
- Suitable for Direct Current & Technical Frequencies
- Oil-Filled Design Ensures Great Long Term Stability <0.01% Over Many Years
GenRad 1620 Capacitance Bridge
- 10-5pF to 11.1 µF, 2-or 3-terminal
- frequency range 20 Hz -20 kHz (or higher)
- 0.01% accuracy, 1-ppm resolution
- reads dissipation factor or conductance
- combines GenRad 1615 Capacitance Bridge, 1232-A Null Detector & 1311-A Oscillator
GenRad 1621 Capacitance Bridge
- Range 10-7 pF to 10 µF, 12-digit readout
- 10-ppm basic accuracy
- frequency range 10 Hz - 100 kHz
- combines GenRad 1616 Capacitance Bridge, 1238-A Null Detector & 1316 Oscillator