  1. 1409 Standard Capacitor

    GenRad 1409 Series Standard Capacitor

    • Values 0.001 µF (100 nF)  to 1000 µF
    • Stability as good as ±0.01 %/year
    • Two-to-five terminal configuration, depending on model
    • Calibration accredited to ISO-17025 included
    • 3 year warranty included
  2. SCA-100pF Capacitance Standard

    SCA Series Capacitance Standard

    • Values from 1 pF to 10,000 µF in any custom value available
    • Stability as good as ±0.01 %/year
    • Two-to-five terminal configuration, depending on model
    • Excellent TC: as low as 10 ppm/°C
    • 3 year warranty included
  3. GenRad 1404 Series Primary Standard Capacitors

    GenRad 1404 Series Primary Standard Capacitors

    • New 5 nF and 10 nF Standards Available
    • A national laboratory standard
    • For calibrating working standards
    • Standard for dissipation factor
    • Available in 10 pF, 100 pF,1000 pF, 10,000 pF
    • 5 Year Warranty Included 
  4. HARS-LX-10-0.001

    HARS-LX Series Decade Resistance Substituter Lab Standard

    • High accuracy - as good as 20 ppm
    • High stability - as good as 5 ppm/yr
    • Over 55 models available with resistance from 1 mΩ to 121.1 MΩ
    • Resolution as good 1 mΩ with a fixed decade or 20 μΩ with a rheostat.
  5. High Frequency Standard Capacitor

    GenRad 1403 Series High Frequency Standard Capacitor

    • Available in values from 0.001 pF - 1000 pF
    • Excellent Performance at high frequencies
    • ISO-17025 Accredited Calibration Included with the Standard
  6. esi RS925

    esi RS925D Resistance Decade

    • High accuracy - 20 ppm + 0.5 mΩ
    • High stability - 20 ppm + 0.5 mΩ
    • Resistance from 10 mΩ to 1.1 MΩ
    • 20 μΩ resolution 
    • Precise fixed minimum resistance
  7. LOM-530 Microohmmeter Calibration Kit for LOM-510A

    LOM-530 Micro-Ohmmeter Calibration Kit

    • Complete set of (5) working standard resistors for calibration of micro-ohmmeters. 
    • Resistance values can be custom modified per your requirement.
    • Calibrates a wide verity of micro-ohmmeters from various manufacturers
  8. Megger Calibration Set of High Resistance Standards

    VRS-100 Series High Resistance Standards

    • Set of nine, ten or eleven resistors - 1 kΩ, 10 kΩ, 100 kΩ,1 MΩ, 10 MΩ, 100 MΩ, 1 GΩ, 10 GΩ, 100 GΩ, 1 TΩ and 10 TΩ , open circuit (Depending on model)
    • High Accuracy - up to 20 ppm
    • Standard voltage: up to 5 kV (voltages of 10 kV are available)
    • Excellent for calibration of Meggers
  9. RTD Precision RTD Simulator

    RTD Series - Precision RTD Simulator

    • Highest accuracy, highest stability, lowest TC of any RTD Simulator available
    • Accuracy for Z Series: 0.005% (0.012 ºC for PT 100)
    • Resolution: 1 mΩ (0.0025 ºC for PT 100)
    • Stability 0.0002% for 24 hours; 0.001% for 12 months
    • PT100 to Resistance Chart with 0.1 mΩ Resolution
  10. SR1-1K Calibration Resistor

    esi SR1 Calibration Resistor

    • New Design, With Improved Specifications
    • Versatile working Calibration Resistor
    • Laboratory standard of high accuracy and stability
    • Adjusted to within 20 ppm of nominal
    • 50 ppm long-term accuracy for most values
  11. DC Current Shunt

    DCCS DC Current Shunt Series

    • Allows for High Current Calibration, up to 60 A
    • Resistances ranges from 100 µΩ - 1 kΩ
    • High Accuracy 0.02%
    • Suitable for Direct Current & Technical Frequencies
    • Oil-Filled Design Ensures Great Long Term Stability <0.01% Over Many Years
  12. 1620 Capacitance Measuring System

    GenRad 1620 Capacitance Bridge

    • 10-5pF to 11.1 µF, 2-or 3-terminal
    • frequency range 20 Hz -20 kHz (or higher)
    • 0.01% accuracy, 1-ppm resolution
    • reads dissipation factor or conductance
    • combines GenRad 1615 Capacitance Bridge, 1232-A Null Detector & 1311-A Oscillator
  13. IET 1621 Precision Capacitance Bridge

    GenRad 1621 Capacitance Bridge

    • Range 10-7 pF to 10 µF, 12-digit readout
    • 10-ppm basic accuracy
    • frequency range 10 Hz - 100 kHz
    • combines GenRad 1616 Capacitance Bridge, 1238-A Null Detector & 1316 Oscillator
  14. SR1010 Resistance Transfer Standard

    esi SR1010 Resistance Transfer Standard

    • Resistance Transfer Standards available in the following values 1 Ω, 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ
    • Initial Accuracy... ± 20PPM of nominal value matched within 10PPM
    • Transfer Accuracy... ± (1PPM + 0.1uΩ at parallel value) for 100:1
    • Transfer Accuracy... ± (1PPM + 1uΩ at series parallel value) for 10:1
    • Long Term Accuracy... ± 50PPM of nominal value
    • Calibration Accuracy... ± 10PPM
  15. Resistance Transfer Standard

    esi SR1030 Series Oil Immersed Transfer Standard

    • Resistance Values of 1 Ω - 100 kΩ
    • Initial Accuracy... ± 20 PPM of nominal value matched within 10 PPM
    • Transfer Accuracy... ± (1 PPM + 0.1uΩ at parallel value) for 100:1
    • Long Term Accuracy... ± 50 PPM of nominal value
    • Calibration Accuracy... ± 10 PPM