Scrolling Catalog

Items 16 to 22 of 22 total

per page
Page:
  1. 1
  2. 2

Set Descending Direction
  1. SR1-1K Calibration Resistor

    esi SR1 Calibration Resistor

    • New Design, With Improved Specifications
    • Versatile working Calibration Resistor
    • Laboratory standard of high accuracy and stability
    • Adjusted to within 20 ppm of nominal
    • 50 ppm long-term accuracy for most values
  2. DC Current Shunt

    DCCS DC Current Shunt Series

    • Allows for High Current Calibration, up to 60 A
    • Resistances ranges from 100 µΩ - 1 kΩ
    • High Accuracy 0.02%
    • Suitable for Direct Current & Technical Frequencies
    • Oil-Filled Design Ensures Great Long Term Stability <0.01% Over Many Years
  3. Resistance Transfer Standard

    esi SR1030 Series Oil Immersed Transfer Standard

    • Resistance Values of 1 Ω - 100 kΩ
    • Initial Accuracy... ± 20 PPM of nominal value matched within 10 PPM
    • Transfer Accuracy... ± (1 PPM + 0.1uΩ at parallel value) for 100:1
    • Long Term Accuracy... ± 50 PPM of nominal value
    • Calibration Accuracy... ± 10 PPM
  4. esi SR102, SR103, SR104

    SR102/103/104 Series

    • Highest accuracy (1 ppm/yr) and stability (±0.5 ppm/yr typical) of any resistance standard
    • Lowest temperature coefficients (< 0.1 ppm/ºC)
    • Available in 3 models: 100Ω, 1000 Ω, 10,000Ω.
    • Has remained the foremost resistance standard, with no equivalent, for over 35 years
    • 5 Year Warranty Included
  5. SRX 4-Terminal

    SRX/SRC Series Economical Resistance Standard

    • Wide range of values - 1 mΩ to 10 TΩ
    • Very stable - up to 10 ppm/yr
    • ISO-17025 Accredited Calibration Included
    • 3 Year Warranty Included
    • Excellent TC - as low as 1 ppm/°C
  6. SR1010 Resistance Transfer Standard

    esi SR1010 Resistance Transfer Standard

    • Resistance Transfer Standards available in the following values 1 Ω, 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ
    • Initial Accuracy... ± 20PPM of nominal value matched within 10PPM
    • Transfer Accuracy... ± (1PPM + 0.1uΩ at parallel value) for 100:1
    • Transfer Accuracy... ± (1PPM + 1uΩ at series parallel value) for 10:1
    • Long Term Accuracy... ± 50PPM of nominal value
    • Calibration Accuracy... ± 10PPM
  7. RCS Series Resistance & Capacitance Box

    RCS Series Resistance & Capacitance Box

    • Combination of Resistance and Capacitance Deacade Box
    • Accurate 0.1% to 4% (Depending on Model)
    • Capacitance Range 100 pF - 100 µF
    • Resistance Range 1 Ω - 10 MΩ
    • Compact, convenient, and rugged

Items 16 to 22 of 22 total

per page
Page:
  1. 1
  2. 2

Set Descending Direction