Scrolling Catalog

14 Item(s)

per page

Set Ascending Direction
  1. Resistance Decade Box

    HARS Series Resistance Decade Box

    • Resistance from 1 mΩ to 111 MΩ
    • Available in double-power version: HARS-X2
    • Wide choice: single through 11 decade units
    • High accuracy - 0.01% (100 ppm)
      • HARS-X: ±(0.01% + 2 mΩ)
      • HARS-B: ±(0.1% + 4 mΩ)
  2. Megger Calibration Set of High Resistance Standards

    VRS-100 Series High Resistance Standards

    • Set of nine, ten or eleven resistors - 1 kΩ, 10 kΩ, 100 kΩ,1 MΩ, 10 MΩ, 100 MΩ, 1 GΩ, 10 GΩ, 100 GΩ, 1 TΩ and 10 TΩ , open circuit (Depending on model)
    • High Accuracy - up to 20 ppm
    • Standard voltage: up to 5 kV (voltages of 10 kV are available)
    • Excellent for Meggers
  3. SRX1 Series NAVAIR Resistance Standard

    SRX1 Series NAVAIR Resistance Standard

    • Range from 1 Ω - 1 MΩ
    • Stabilities as good as 5 ppm
    • Minimal Change from power cycling
    • The US Navy's Resistance Standard
  4. DC Current Shunt

    DCCS DC Current Shunt Series

    • Allows for High Current Calibration, up to 60 A
    • Resistances ranges from 100 µΩ - 1 kΩ
    • High Accuracy 0.02%
    • Suitable for Direct Current & Technical Frequencies
    • Oil-Filled Design Ensures Great Long Term Stability <0.01% Over Many Years
  5. Micro-Ohmmeter

    LOM-510A Micro-Ohmmeter

    • 1 μΩ resolution, 4½ digits
    • Range: 1 μΩ - 200 Ω
    • 0.02% basic accuracy
    • Costs around 50% less then its peer instruments
    • 4-Wire Design to eliminate lead resistance
  6. PRS Series Programmable Resistance Decade Box

    PRS Series Programmable Resistance Decade Box

    • IEEE or RS232 Programmable Decade Resistor
    • Wide range and resolution: 1 mΩ to 100 MΩ
    • Available at accuracies of : 0.01%, 0.02%, 0.05%, 0.1%, 0.5%, and 1%
    • Special RTD and custom configurations
    • Dual / Combo rackmount models ( examples: resistance & capacitance )
  7. SRX 4-Terminal Resistance Standard

    SRX/SRC Series Economical Resistance Standard

    • Wide range of values - 1 mΩ to 10 TΩ
    • Very stable - up to 10 ppm/yr
    • ISO-17025 Accredited Calibration Included
    • 3 Year Warranty Included
    • Excellent TC - as low as 1 ppm/°C
  8. Transfer Standard

    HATS-Y Series High Resistance Transfer Standard

    • Resistance Values 100 kΩ, 1 MΩ, 10 MΩ, 100 MΩ
    • Initial Accuracy...As good as 10 ppm nominal value matched within 10 ppm
    • Transfer Accuracy... ± 2 ppm (Typical Short-term Repeatability)
    • 1 Year Stability : As good as 10 ppm
  9. RS-201W

    RS Series Resistance Substitution Box

    • Accurate 0.1% to 1%
    • Wide range from 0.01 Ω - 100 MΩ
    • Broad choice of standard and optional models with many powerful features
    • Compact, convenient, and rugged
  10. OhmSOURCE with Leads

    ohmSource Resistance Decade Box / RTD Simulator

    • The revolutionary ohmSOURCE Microprocessor Controlled Resistance Decade Boxes are like nothing you have ever seen before!
    • Two cost-effective models available
    • Accuracy's as tight as 0.01%, with resolution as good as 0.01Ω
    • Engineered as an ideal RTD Calibrator 
  11. HRRS Series High Resistance Decade Box

    HRRS Series High Resistance Decade Box

    • Resistance from 100 Ω to 100 GΩ
    • High-accuracy: up to .01%, 3 Accuracy Classes Available
    • Voltage up to 2000 V
    • Excellent TC: as low as 5 ppm/°C
    • Low voltage coefficient: as low as 0.2 ppm/V
    • High-performance solid silver-alloy switches
    • Rack mounting available
  12. HRRS-7 Decade

    HRRS-5 kV & 10 kV Series - High Resistance Decade Box

    • Resistance from 1 Ω to 10 TΩ +
    • High-accuracy: up to .01%; 3 Accuracy Classes
    • Max voltage of 5 kV or 10 kV; 2 Series
    • Ideal for the calibration of meggers
    • Low voltage coefficient: as low as 0.2 ppm/V
    • High-stability: up to 10 ppm/yr
    • Special and custom configurations available
  13. HPRS Series High Power Resistance Decade Box

    HPRS Series High Power Resistance Decade Box

    • Resistance from 1 mΩ to 10 MΩ
    • Power Rating : 225 W/decade, 250 W max. or higher (Contact IET for Custom Higher Power Units)
    • Accuracy: 0.5% or 1%
    • Voltage Rating: 1000 V or higher
    • Special and custom configurations available
  14. HATS-LR Low Resistance Transfer Standard

    HATS-LR Low Resistance Transfer Standard

    • Values from 1 Ω - 100 kΩ
    • Initial Accuracy... As good as 10 ppm of nominal value
    • Transfer Accuracy... ± (1 ppm + 0.1uΩ at parallel value) for 10:1 & 100:1 ratios
    • Long Term Accuracy... ± 10 ppm/year
    • Calibration Accuracy... ± 5 ppm

14 Item(s)

per page

Set Ascending Direction