Scrolling Catalog

Items 31 to 45 of 71 total

per page
Page:
  1. 1
  2. 2
  3. 3
  4. 4
  5. 5

Set Descending Direction
  1. LS-400 Inductance Box

    LS Series Inductance Decade Box

    • Accurate 2%
    • Cost effective for lab or educational uses
    • Wide range from 50 µH - 10 H
    • Broad choice of 3 standard models, the LS-400, LS-400A, LS-400L
    • Compact, convenient, and rugged
    • Direct reading and Error proof 
    • Color Coded
  2. PCS Bench

    PCS Series Programmable Capacitance Decade Box

    • The world's only programmable capacitance decade box
    • Wide range and resolution: 1 pF to 100 µF
    • Available at accuracies of : 0.5%, 1% and 4%
    • LabVIEW Drivers for IEEE-488.2 and RS-232 Versions
    • Dual / Combo rackmount models ( examples:Resistance & Capacitance )
  3. GenRad 1423-A Decade Capacitor

    GenRad 1423-A Decade Capacitor

    • Range 100pF - 1.111 µF
    • ±0.05% accuracy
    • two- or three-terminal connection
  4. 1422-CB 3-Terminal Air Capacitor

    GenRad 1422 Series Variable Air Capacitors

    • Range as low as 0.002 pF and as high as 1150 pF (Depending on Model)
    • Stability: better than 0.02% full scale per year
    • Settable to 40 ppm
    • Low temperature coefficient, low losses
    • Wide selection to suit needs
  5. GenRad 1412-BC Decade Capacitance Box

    GenRad 1412-BC Decade Capacitance Box

    • Range from 50 pF to 1.11115 µF
    • Resolution better than 1 pF
    • Accuracy 0.5% + 5 pF
    • Low loss, leakage, dielectric absorption
    • Verification of calibration of LCR meters, multimeters, and instrumentation
  6. 1417 Capacitance Standard

    GenRad 1417 Capacitance Standard 1 uF - 1 F

    • 7 Switch-Selected Standard Capacitance Values: 1 µF, 10 µF, 100 µF, 1 mF, 10 mF,100 mF, 1 F
    • 3 Switch-Selected Test Frequencies: 100 Hz,
      120 Hz, 1 kHz
    • 0.25% direct-reading capacitance accuracy
    • 0.1% or better ratio accuracy
  7. 1412-B Decade Capacitor

    GenRad 1419 Series Decade Capacitor

    • Range from 100 pF to 1.1 µF
    • Choice of 3 models
    • Accuracy as good as 0.5%
    • Capacitance and dissipation factor vary only slightly with frequency from dc through the audio frequency range.
  8. Variac

    Variac Selection Guide

    • IET Labs offers over 500 different Variacs from General Radio/Technipower and Staco.  
    • To find the best Variac model for your application use the selection filter from this page 
  9. Sound Level Meter

    GenRad 1565-B Sound-Level Meter

    • 40 to 140 dB
    • ANSI Type 2 A, B, C weighting
    • Fast/slow meter response
    • MESA approved
    • Convenient pocket proportions -small and light
  10. esi RS925

    esi RS925D Resistance Decade

    • High accuracy - 20 ppm + 0.5 mΩ
    • High stability - 20 ppm + 0.5 mΩ
    • Resistance from 10 mΩ to 1.1 MΩ
    • 20 μΩ resolution 
    • Precise fixed minimum resistance
  11. HPRS-F-7-0.001 High Power Decade Resistance Box

    HPRS Series High Power Resistance Decade Box

    • Resistance from 1 mΩ to 10 MΩ
    • Power Rating : 225 W/decade, 250 W max. or higher (Contact IET for Custom Higher Power Units)
    • Accuracy: 0.5% or 1%
    • Special and custom configurations available
  12. KVD-700 Voltage Divider

    KVD-700 Precision Kelvin-Varley Voltage Divider

    • Primary Calibration grade 100 kΩ Kelivin-Varley Voltage Divider
    • Used by National Measurement Institutes around the world
    • Built in Wheatstone Bridge allows for a self calibrating circuit
    • Employees "Zero tempco foil resistors"
    • Direct replacement for Fluke 720A

  13. LOM-530 Microohmmeter Calibration Kit for LOM-510A

    LOM-530 Micro-Ohmmeter Calibration Kit

    • Complete set of (5) working standard resistors for calibration of micro-ohmmeters. 
    • Resistance values can be custom modified per your requirement.
    • Calibrates a wide verity of micro-ohmmeters from various manufacturers
  14. Megger Calibration Set of High Resistance Standards

    VRS-100 Series High Resistance Standards

    • Set of nine, ten or eleven resistors - 1 kΩ, 10 kΩ, 100 kΩ,1 MΩ, 10 MΩ, 100 MΩ, 1 GΩ, 10 GΩ, 100 GΩ, 1 TΩ and 10 TΩ , open circuit (Depending on model)
    • High Accuracy - up to 20 ppm
    • Standard voltage: up to 5 kV (voltages of 10 kV are available)
    • Excellent for calibration of Meggers
  15. RTD Precision RTD Simulator

    RTD Series - Precision RTD Simulator

    • Highest accuracy, highest stability, lowest TC of any RTD Simulator available
    • Accuracy for Z Series: 0.005% (0.012 ºC for PT 100)
    • Resolution: 1 mΩ (0.0025 ºC for PT 100)
    • Stability 0.0002% for 24 hours; 0.001% for 12 months
    • PT100 to Resistance Chart with 0.1 mΩ Resolution

Items 31 to 45 of 71 total

per page
Page:
  1. 1
  2. 2
  3. 3
  4. 4
  5. 5

Set Descending Direction