  1. GenRad 1538-A Stroboscope

    GenRad 1538-A Stroboscope

    • The highest flashing rates for a stroboscope-up to 150,000 Flashes per mn,
    • Flash duration from 0.5 μs to 3.0 μs for clear, crisp images.
    • Accessory energy-storage capacitor 1538-P4 for very short single flashes.
    • High accuracy stroboscope — rpm measurements can be made to ± 1%
  2. RCS Series Resistance & Capacitance Box

    RCS Series Resistance & Capacitance Box

    • Combination of Resistance and Capacitance Deacade Box
    • Accurate 0.1% to 4% (Depending on Model)
    • Capacitance Range 100 pF - 100 µF
    • Resistance Range 1 Ω - 10 MΩ
    • Compact, convenient, and rugged
  3. esi SR1050 Series 1M & 10 M Resistance Transfer Standard

    esi SR1050 Series 1M & 10 M Resistance Transfer Standard

    • Resistance Values 1 MΩ & 10 MΩ
    • Initial Accuracy... ± 25 or 30 ppm of nominal value matched within 10 ppm
    • Transfer Accuracy... ± 2 ppm (Typical Short-term Repeatability)
    • Calibration Accuracy... ± 10 or 15 ppm
  4. SRX1 Series NAVAIR Resistance Standard

    SRX1 Series NAVAIR Resistance Standard

    • Range from 1 Ω - 1 MΩ
    • Stabilities as good as 5 ppm
    • Minimal Change from power cycling
    • The US Navy's Resistance Standard
  5. SR102/103/104 Series

    SR102/103/104 Series

    • Highest accuracy (1 ppm/yr) and stability (±0.5 ppm/yr typical) of any resistance standard
    • Lowest temperature coefficients (< 0.1 ppm/ºC)
    • Available in 3 models: 100Ω, 1000 Ω, 10,000Ω.
    • Has remained the foremost resistance standard, with no equivalent, for over 35 years
    • 5 Year Warranty Included
  6. SRX 4-Terminal Resistance Standard

    SRX/SRC Series Economical Resistance Standard

    • Wide range of values - 1 mΩ to 10 TΩ
    • Very stable - up to 10 ppm/yr
    • ISO-17025 Accredited Calibration Included
    • 3 Year Warranty Included
    • Excellent TC - as low as 1 ppm/°C
  7. Resistance Transfer Standard

    esi SR1030 Series Oil Immersed Transfer Standard

    • Resistance Values of 1 Ω - 100 kΩ
    • Initial Accuracy... ± 20 PPM of nominal value matched within 10 PPM
    • Transfer Accuracy... ± (1 PPM + 0.1uΩ at parallel value) for 100:1
    • Long Term Accuracy... ± 50 PPM of nominal value
    • Calibration Accuracy... ± 10 PPM
  8. esi SR1010 Resistance Transfer Standard

    esi SR1010 Resistance Transfer Standard

    • Resistance Transfer Standards available in the following values 1 Ω, 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ
    • Initial Accuracy... ± 20PPM of nominal value matched within 10PPM
    • Transfer Accuracy... ± (1PPM + 0.1uΩ at parallel value) for 100:1
    • Transfer Accuracy... ± (1PPM + 1uΩ at series parallel value) for 10:1
    • Long Term Accuracy... ± 50PPM of nominal value
    • Calibration Accuracy... ± 10PPM
  9. Binding Post Series

    BP-1000 Binding Posts Series- Low emf, Rugged, High-Current

    • Very high current rating: 30 amps
    • Lowest impedance of any binding posts <50 μΩ
    • Rugged design
    • Caps resistant to fracture
    • Very low thermal emf
    • Gold-plated tellurium copper body
    • Polycarbonate insulators
  10. Rackmount Shelf

    RM Series General Purpose Test Equipment Rack Mount Shelves

    • Fits standard 19" rack mount cabinets, built to EIA-310-D
    • Available in standard rack mount heights
    • Capable of supporting most electrical instruments of up to 150 pounds
    • Ventilation holes on the bottom allow for instrument cooling
    • Velcro strips are included to help secure instruments on the shelf
    • Mounting hardware available upon request
  11. GenRad 1982 Precision Sound Level Meter

    GenRad 1982 Precision Sound Level Meter

    • a versatile, all-purpose instrument precision sound-level meter peak and impulse noise meter octave-band analyzer
    • ideal for OSHA and a broad variety of noise measurements
    • digital and analog displays for error-free reading
    • compact and lightweight (3 lb) for easy handling
    • approved by MSHA and NIOSH
  12. Sound Level Calibrator

    GenRad 1562-A Sound Level Calibrator

    • Workhorse of the acoustics field
    • Calibrates most sound-level meters
    • Generates standard levels and frequencies
    • Adaptable to various microphone sizes
    • Use in the lab or in the field
  13. Externally Triggered

    GenRad 1539-A Externally Triggered Stroboscope

    • Small size and light weight.
    • Light source on flexible cable for convenient positioning.
    • Can be triggered by several methods.
    • For machine maintenance, Real time inspection of moving parts, Printing press applications, Motor troubleshooting, For stopping motion