Scrolling Catalog
-
GenRad 1538-A Stroboscope
- The highest flashing rates for a stroboscope-up to 150,000 Flashes per mn,
- Flash duration from 0.5 μs to 3.0 μs for clear, crisp images.
- Accessory energy-storage capacitor 1538-P4 for very short single flashes.
- High accuracy stroboscope — rpm measurements can be made to ± 1%
-
RCS Series Resistance & Capacitance Box
- Combination of Resistance and Capacitance Deacade Box
- Accurate 0.1% to 4% (Depending on Model)
- Capacitance Range 100 pF - 100 µF
- Resistance Range 1 Ω - 10 MΩ
- Compact, convenient, and rugged
-
GenRad 1408 Series Standard Capacitors
short description -
esi SR1050 Series 1M & 10 M Resistance Transfer Standard
- Resistance Values 1 MΩ & 10 MΩ
- Initial Accuracy... ± 25 or 30 ppm of nominal value matched within 10 ppm
- Transfer Accuracy... ± 2 ppm (Typical Short-term Repeatability)
- Calibration Accuracy... ± 10 or 15 ppm
-
SRX1 Series NAVAIR Resistance Standard
- Range from 1 Ω - 1 MΩ
- Stabilities as good as 5 ppm
- Minimal Change from power cycling
- The US Navy's Resistance Standard
-
SR102/103/104 Series
- Highest accuracy (1 ppm/yr) and stability (±0.5 ppm/yr typical) of any resistance standard
- Lowest temperature coefficients (< 0.1 ppm/ºC)
- Available in 3 models: 100Ω, 1000 Ω, 10,000Ω.
- Has remained the foremost resistance standard, with no equivalent, for over 35 years
- 5 Year Warranty Included
-
SRX/SRC Series Economical Resistance Standard
- Wide range of values - 1 mΩ to 10 TΩ
- Very stable - up to 10 ppm/yr
- ISO-17025 Accredited Calibration Included
- 3 Year Warranty Included
- Excellent TC - as low as 1 ppm/°C
-
esi SR1030 Series Oil Immersed Transfer Standard
- Resistance Values of 1 Ω - 100 kΩ
- Initial Accuracy... ± 20 PPM of nominal value matched within 10 PPM
- Transfer Accuracy... ± (1 PPM + 0.1uΩ at parallel value) for 100:1
- Long Term Accuracy... ± 50 PPM of nominal value
- Calibration Accuracy... ± 10 PPM
-
esi SR1010 Resistance Transfer Standard
- Resistance Transfer Standards available in the following values 1 Ω, 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ
- Initial Accuracy... ± 20PPM of nominal value matched within 10PPM
- Transfer Accuracy... ± (1PPM + 0.1uΩ at parallel value) for 100:1
- Transfer Accuracy... ± (1PPM + 1uΩ at series parallel value) for 10:1
- Long Term Accuracy... ± 50PPM of nominal value
- Calibration Accuracy... ± 10PPM
-
BP-1000 Binding Posts Series- Low emf, Rugged, High-Current
- Very high current rating: 30 amps
- Lowest impedance of any binding posts <50 μΩ
- Rugged design
- Caps resistant to fracture
- Very low thermal emf
- Gold-plated tellurium copper body
- Polycarbonate insulators
-
RM Series General Purpose Test Equipment Rack Mount Shelves
- Fits standard 19" rack mount cabinets, built to EIA-310-D
- Available in standard rack mount heights
- Capable of supporting most electrical instruments of up to 150 pounds
- Ventilation holes on the bottom allow for instrument cooling
- Velcro strips are included to help secure instruments on the shelf
- Mounting hardware available upon request
-
GenRad 1557-A Vibration Calibrator
short description -
GenRad 1982 Precision Sound Level Meter
- a versatile, all-purpose instrument precision sound-level meter peak and impulse noise meter octave-band analyzer
- ideal for OSHA and a broad variety of noise measurements
- digital and analog displays for error-free reading
- compact and lightweight (3 lb) for easy handling
- approved by MSHA and NIOSH
-
GenRad 1562-A Sound Level Calibrator
- Workhorse of the acoustics field
- Calibrates most sound-level meters
- Generates standard levels and frequencies
- Adaptable to various microphone sizes
- Use in the lab or in the field
- Workhorse of the acoustics field
-
GenRad 1539-A Externally Triggered Stroboscope
- Small size and light weight.
- Light source on flexible cable for convenient positioning.
- Can be triggered by several methods.
- For machine maintenance, Real time inspection of moving parts, Printing press applications, Motor troubleshooting, For stopping motion