Resistance
-
1865+ Digital Megohmmeter I/R Tester
- Measurements from 1kΩ to 100TΩ, with Auto Ranging
- 0.5% measurement accuracy
- Programmable Test Voltage from 1 to 1000VDC
- RS-232 Flash Drive and PLC Interfaces Standard, IEEE-488 Optional
-
DCCS Current Shunt Series
- Allows for High Current Calibration
- High Accuracy 0.02%
- Suitable for Direct Current & Technical Frequencies
- Oil-Filled Design Ensures Great Long Term Stability <0.01% Over Many Years
-
esi / Tegam DB62 Decade Resistor
- Precision accuracy of 0.01%
- Resistance range from 0.01 Ω to 11.1111 MΩ
- 4 models available,, each covering six decades
-
esi RS925D Decade Resistance Substituter
- High accuracy - 20 ppm + 0.5 mΩ
- High stability - 20 ppm + 0.5 mΩ
- Resistance from 10 mΩ to 1.1 MΩ
- 20 μΩ resolution
-
esi SR1 Standard Resistor
short description -
esi SR1010 Resistance Transfer Standard
- Initial Accuracy... ± 20PPM of nominal value matched within 10PPM
- Transfer Accuracy... ± (1PPM + 0.1uΩ at parallel value) for 100:1
- Transfer Accuracy... ± (1PPM + 1uΩ at series parallel value) for 10:1
- Long Term Accuracy... ± 50PPM of nominal value
- Calibration Accuracy... ± 10PPM
-
esi SR1030 Series Oil Immersed Transfer Standard
- Resistance Values of 1 Ω - 100 kΩ
- Initial Accuracy... ± 20 PPM of nominal value matched within 10 PPM
- Transfer Accuracy... ± (1 PPM + 0.1uΩ at parallel value) for 100:1
- Long Term Accuracy... ± 50 PPM of nominal value
-
esi SR1050 Series 1M & 10 M Resistance Transfer Standard
- Resistance Values 1 MΩ & 10 MΩ
- Initial Accuracy... ± 25 or 30 ppm of nominal value matched within 10 ppm
- Transfer Accuracy... ± 2 ppm (Typical Short-term Repeatability)
- Calibration Accuracy... ± 10 or 15 ppm
-
GenRad 1433 Series Decade Resistor
- Precision accuracy of +0.01%
- Resistance range from 1 mΩ to 111.11111111 MΩ
- 36 models available, 3 to 11 dials
- Dust proof, long life switches with solid silver contacts
- Excellent frequency characteristics
-
GenRad 1863 Megohmmeter
- 5 Test Voltages from 50, 100, 200, 250, 500 VDC
- Rugged and Portable Analog Megohmmeter
- Up to 3% Accuracy
- Suggested Equipment in Boeing Service Bulletins for DC-10, 747 and others
- Reliable High Quality Instrument Designed to Last up to 30 years
-
GenRad 1864 Megohmmeter
- 200 Test Voltages from 10 V to 1090 VDC
- Rugged and Portable Analog Megohmmeter
- Up to 3% Accuracy
- 50 kΩ to 200 TΩ Measurement Range
- Reliable High Quality Instrument Designed to Last up to 30 years
-
HARS Series Resistance Decade Box
- Resistance from 1 mΩ to 111 MΩ, from 1 to 11 Decades
- High accuracy - 0.01% (100 ppm) or 0.1% depending on Model
- Available in double-power version: HARS-X2
- Very low zero-resistance: <1 mΩ per decade
-
HATS-LR Low Resistance Transfer Standard
- Values from 1 Ω - 100 kΩ
- Initial Accuracy... As good as 10 ppm of nominal value
- Transfer Accuracy... ± (1 ppm + 0.1uΩ at parallel value) for 10:1 & 100:1 ratios
- Long Term Accuracy... ± 10 ppm/year
- Calibration Accuracy... ± 5 ppm
-
HATS-Y Series High Resistance Transfer Standard
- Resistance Values 100 kΩ, 1 MΩ, 10 MΩ, 100 MΩ
- Initial Accuracy...As good as 10 ppm nominal value matched within 10 ppm
- Transfer Accuracy... ± 2 ppm (Typical Short-term Repeatability)
- 1 Year Stability : As good as 10 ppm
-
HPRS Series High Power Resistance Decade Box
- Resistance from 1 mΩ to 10 MΩ
- Power Rating : 225 W/decade, 250 W max. or higher
- Accuracy: 0.5% or 1%
- Voltage Rating: 1000 V or higher
- Special and custom configurations available