GenRad 1840-A Output Power Meter

1840-A Output Power Meter

Double click on above image to view full picture

Zoom Out
Zoom In
More Views

Photo represents example of series. See datasheet for more details on any specific model.

  • Power output of oscillators, amplifiers, preamplifiers, transformers, transducers, and low-frequency lines.
  • Output impedance, by adjustment of the load to yield maximum power indication.
  • Frequency-response characteristics of amplifiers, transformers, and other audio-frequency devices.
Priced at $3,895

Estimated Delivery is 5 to 7 weeks

Repair/Calibration Quote Technical Support Request
The General Radio 1840A measures audio-frequency power into any desired load. Its important uses include the measurement of:

  • *Power output of oscillators, amplifiers, preamplifiers, transformers, transducers, and low-frequency lines.
  • *Output impedance, by adjustment of the load to yield maximum power indication.
  • *Frequency-response characteristics of amplifiers, transformers, and other audio-frequency devices.

This instrument is basically a multi-tapped audio-frequency transformer with a fixed secondary load. Its two front-panel switches connect eight identical primary windings and six secondary taps in various combinations to provide a total of 48 different primary impedances.

The maximum power rating can be extended for any given impedance with the use of simple T-network attenuator, design data for which are supplied with the instrument.

 

 

 

Power Range:
0.1 mW to 20 watts in five ranges, 40 Hz to 20 kHz; maximum rating is reduced by up to 50% (at 25 Hz), depending on impedance selected.

An auxiliary dB scale on the meter reads from -15 to +3 dB, referred to 1 mW.

Impedance Range:
0.6 Ω to 32 kΩ in two ranges; yielding 48 individual impedances spaced approximately 2 apart.

Accuracy
Impedance:
at 1 kHz, ±6% max, -0.5% avg;
70 Hz to 2.5 kHz, ±7% above 10 kW;
70 Hz to 5 kHz, ±7% below 10 kW;
at 20 Hz, -15% max, -8% avg;
at 20 kHz, ±50% max, ±12% avg
When impedance is specified, accuracy applies at full-scale on all ranges and impedances at 1 kHz;
when frequency ranges are specified, accuracy is at full-scale at ranges ≥20 mW at the specified impedances.
When a frequency limit is specified, accuracy is at full-scale at all impedances

Power:
at 1 kHz, ±0.3 dB;
50 Hz to 6 kHz, ±0.5 dB;
30 Hz to 10 kHz, ±1 dB;
at 20 Hz, -1.5 dB max, -1 dB avg;
at 20 kHz, -5 dB max, ±1.5 dB avg.

Waveform Error:
Meter will indicate true rms with as much as 20% second and third harmonics present in the input signal.

General
Cabinet:
Convertible bench cabinet, aluminum panel. Cabinet has extension legs to permit instrument to be used in a tilted position. Panel extensions,

Type 480-P212 Adaptor Plate Sets, are available for relay-rack mounting.

Dimensions: Panel - 12” W x 3.5” H (305 x 90 mm);

depth behind panel - 6.5” (170 mm)

Net Weight: 10.8 pounds (4.9 kg)