Resistance

Filter Ideal Instrument
  1. SRX/SRC Series Economical Resistance Standard
    • Wide range of values - 1 mΩ to 10 TΩ
    • Very stable - up to 10 ppm/yr
    • ISO-17025 accredited calibration included
    • 3 Year warranty included
    • Excellent TC - as low as 1 ppm/°C
  2. esi SR1 Calibration Resistor
    • New Design, with improved specifications
    • Versatile working calibration resistor
    • Laboratory standard of high accuracy and stability
    • Adjusted to within 20 ppm of nominal
    • 50 ppm long-term accuracy for most values
  3. DCCS DC Current Shunt Series
    • Allows for high current calibration, up to 60 A
    • Resistances ranges from 100 µΩ - 1 kΩ
    • High accuracy 0.02%
    • Suitable for direct current & audio frequencies
    • Oil-filled design ensures great long term stability <0.01% over many years
  4. HARS-LX Series Decade Resistance Substituter Lab Standard
    • High accuracy - as good as 20 ppm
    • High stability - as good as 5 ppm/yr
    • Over 55 models available with resistance from 1 mΩ to 121.1 MΩ
    • Resolution as good 1 mΩ with a fixed decade or 20 μΩ with a rheostat.
  5. RTD Series - Precision RTD Simulator
    • Highest accuracy, highest stability, lowest TC of any RTD Simulator available
    • Accuracy for Z Series: 0.005% (0.012 ºC for PT 100)
    • Resolution: 1 mΩ (0.0025 ºC for PT 100)
    • Stability 0.0002% for 24 hours; 0.001% for 12 months
  6. SRL Series Precision Resistance Standard
    • Very stable - up to 2 ppm/yr
    • Wide range of values - 1 mΩ to 1.9 TΩ,
    • Used by National Measurment Institutes across the world
    • 3 Year warranty included
  7. LOM-530 Micro-Ohmmeter Calibration Kit
    • Complete set of (5) working standard resistors for calibration of micro-ohmmeters. 
    • Resistance values can be custom modified per your requirement.
    • Calibrates a wide verity of micro-ohmmeters from various manufacturers
  8. esi SR1010 Resistance Transfer Standard
    • Resistance Transfer Standards available in the following values 1 Ω, 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ
    • Initial Accuracy... ± 20PPM of nominal value matched within 10PPM
    • Transfer Accuracy... ± (1PPM + 0.1uΩ at parallel value) for 100:1
    • Transfer Accuracy... ± (1PPM + 1uΩ at series parallel value) for 10:1
    • Long Term Accuracy... ± 50PPM of nominal value
    • Calibration Accuracy... ± 10PPM
  9. SRR Series High Accuracy Standard Resistor
    • High accuracy four-terminal standard resistors
    • Resistance Value of: 0.0001 Ω, 0.001 Ω, 0.01 Ω, 0.1 Ω
  10. VRS-100 Series High Resistance Standards
    • Set of nine, ten or eleven resistors - 1 kΩ, 10 kΩ, 100 kΩ,1 MΩ, 10 MΩ, 100 MΩ, 1 GΩ, 10 GΩ, 100 GΩ, 1 TΩ and 10 TΩ , open circuit (Depending on model)
    • High Accuracy - up to 20 ppm
    • Standard voltage: up to 5 kV (voltages of 10 kV are available)
    • Excellent for calibration of Meggers
  11. esi SR1030 Series Oil Immersed Transfer Standard
    • Resistance Values of 1 Ω - 100 kΩ
    • Initial Accuracy... ± 20 PPM of nominal value matched within 10 PPM
    • Transfer Accuracy... ± (1 PPM + 0.1uΩ at parallel value) for 100:1
    • Long Term Accuracy... ± 50 PPM of nominal value
    • Calibration Accuracy... ± 10 PPM
  12. SR102/103/104 Series
    • Highest accuracy (1 ppm/yr) and stability (±0.5 ppm/yr typical) of any resistance standard
    • Lowest temperature coefficients (< 0.1 ppm/ºC)
    • Available in 3 models: 100Ω, 1000 Ω, 10,000Ω.
    • Has remained the foremost resistance standard, with no equivalent, for over 35 years
    • 5 Year Warranty Included
  13. PRS-DMM Programmable Self-Adjusting Resistance Standard
    • Patent pending
    • Software leverages the accuracy of an 8.5 digit DMM, with the versatility of the PRS-300 Programmable Resistor to make the most revolutionary standard resistor ever manufactured
    • Resistance Range: 0.1 Ω to 20 MΩ
    • Resolution: 1 μΩ
    • Accuracies better than 20 ppm; source resistance with the same accuracy that your 8.5 Digit DMM can measure.
    • All you need to do is enter the target resistance. The software uses the DMM to measure the resistance being sourced by the PRS-300 and readjusts the source resistance as close as possible to the target resistance.
    • Software automatically provides the measurement uncertainties of every measurement
  14. esi SR1050 Series 1M & 10 M Resistance Transfer Standard
    • Resistance Values 1 MΩ & 10 MΩ
    • Initial Accuracy... ± 25 or 30 ppm of nominal value matched within 10 ppm
    • Transfer Accuracy... ± 2 ppm (Typical Short-term Repeatability)
    • Calibration Accuracy... ± 10 or 15 ppm
  15. esi RS925D Resistance Decade
    • High accuracy - 20 ppm + 0.5 mΩ
    • High stability - 20 ppm + 0.5 mΩ
    • Resistance from 10 mΩ to 1.1 MΩ
    • 20 μΩ resolution 
    • Precise fixed minimum resistance