Resistance Standards

Filter Ideal Instrument
  1. PRS-370 Self-Adjusting Programmable Resistance Box & RTD Simulator
    • Resistance range: 0.1 Ω to 20 MΩ with a Resolution of 1 μΩ or 6 digits
    • Precision lab grade Resistor Standard with accuracy <10 ppm when used in DMM mode or <70 ppm accuracy in source mode.
    • Manual or Programmable decade resistor with IEEE interface and Labview drivers
    • No long term maintenance or calibration cost -with an 5 year warranty
    • Designed for customers who own an 8.5 digit DMM (Fluke 8508A or Keysight 3458)
    • The most revolutionary decade resistor ever!
  2. SR102/103/104 Series
    • Highest accuracy (1 ppm/yr) and stability (±0.5 ppm/yr typical) of any resistance standard
    • Lowest temperature coefficients (< 0.1 ppm/ºC)
    • Available in 3 models: 100Ω, 1000 Ω, 10,000Ω.
    • Has remained the foremost resistance standard, with no equivalent, for over 35 years
    • 5 Year Warranty Included
  3. SRAC Standard Resistors Designed for Use At AC
    • Precision ac/dc resistance standards designed for use up to 10 kHz
    • Available for values from 1 mΩ - 10 MΩ, Contact IET for custom values
    • Very stable <20 ppm/year for most values at ac and dc
    • Calibrated at dc and 1 kHz
  4. HARS-LX Series Decade Resistance Substituter Lab Standard
    • High accuracy - as good as 20 ppm
    • High stability - as good as 5 ppm/yr
    • Over 55 models available with resistance from 1 mΩ to 121.1 MΩ
    • Resolution as good 1 mΩ with a fixed decade or 20 μΩ with a rheostat.
  5. esi SR1010 Resistance Transfer Standard
    • Resistance Transfer Standards available in the following values 1 Ω, 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ
    • Initial Accuracy... ± 20PPM of nominal value matched within 10PPM
    • Transfer Accuracy... ± (1PPM + 0.1uΩ at parallel value) for 100:1
    • Transfer Accuracy... ± (1PPM + 1uΩ at series parallel value) for 10:1
    • Long Term Accuracy... ± 50PPM of nominal value
    • Calibration Accuracy... ± 10PPM
  6. esi SR1030 Series Oil Immersed Transfer Standard
    • Resistance Values of 1 Ω - 100 kΩ
    • Initial Accuracy... ± 20 PPM of nominal value matched within 10 PPM
    • Transfer Accuracy... ± (1 PPM + 0.1uΩ at parallel value) for 100:1
    • Long Term Accuracy... ± 50 PPM of nominal value
    • Calibration Accuracy... ± 10 PPM
  7. esi SR1050 Series 1M & 10 M Resistance Transfer Standard
    • Resistance Values 1 MΩ & 10 MΩ
    • Initial Accuracy... ± 25 or 30 ppm of nominal value matched within 10 ppm
    • Transfer Accuracy... ± 2 ppm (Typical Short-term Repeatability)
    • Calibration Accuracy... ± 10 or 15 ppm
  8. esi SR1 Calibration Resistor
    • New Design, with improved specifications
    • Versatile working calibration resistor
    • Laboratory standard of high accuracy and stability
    • Adjusted to within 20 ppm of nominal
    • 50 ppm long-term accuracy for most values