Scrolling Catalog

Filter Ideal Instrument
  1. HACS-Z Series High Accuracy Decade Capacitance Box
    • Range from 1 pF to 11,111 µF
    • High accuracy of 0.05% + 0.5 pF
    • Units available with as few as 3 and as many as 11 decades
    • Excellent Stability 100 ppm per year
    • 3-Terminal shielded construction
  2. GenRad 1482 Series Inductance Standard
    • Stable within ±0.01% per year
    • 18 Models values from 1 µH to 10 H
    • Low, known temperature coefficient
    • 3 year warranty included
  3. PRS-200 Series Programmable Resistance Decade Box
    • IEEE, RS232 or Ethernet Programmable Decade Resistor
    • Wide range and resolution: 1 mΩ to 100 MΩ
    • Available at accuracies of : 0.01%, 0.02%, 0.05%, 0.1%, 0.5%, and 1%
    • Special RTD and custom configurations
    • Dual / Combo rackmount models ( examples: Resistance & Capacitance or Resistance & Inductance)
  4. GenRad 1491 D, G Precision Decade Inductor
    • Most accurate decade inductor commercially available, accuracy's as good as 0.8%
    • Inductance range from 1 mH or 100 µH to 11 H
    • Shielded toroidal cores for small mutual inductance and minimal effect from external fields
    • Sealed against moisture for long-term stability
  5. GenRad 1986 Omnical Sound Level Calibrator -New
    • Capable of testing all the basic characteristics of virtually any acoustic instrument or system
    • Multi-level outputs 74, 84, 94, 104, or 114 dB re 20µPa output
    • Multi-frequency outputs 125, 250, 500, 1000, 2000 or 4000 Hz
    • Portable battery-operated
  6. HARS-LX Series Decade Resistance Substituter Lab Standard
    • High accuracy - as good as 20 ppm
    • High stability - as good as 5 ppm/yr
    • Over 55 models available with resistance from 1 mΩ to 121.1 MΩ
    • Resolution as good 1 mΩ with a fixed decade or 20 μΩ with a rheostat.
  7. HRRS-5 kV & 10 kV Series - High Resistance Decade Box
    • Resistance from 10 Ω to 11 TΩ
    • High-accuracy: up to .01%; 3 Accuracy Classes
    • Max voltage of 5 kV or 10 kV; 2 Series
    • Ideal for the calibration of meggers
  8. CS Series Cost Effective Capacitance Decade Box
    • Accurate 0.5% to 4%
    • Wide range from 50 pF - 1000 µF (depending on model)
    • Resolutions as good as 1 pF (depending on model)
    • Broad choice of standard and optional models with many powerful features
    • Compact, convenient, and rugged
  9. GenRad 1403 Series High Frequency Standard Capacitor
    • Available in values from 0.001 pF - 1000 pF
    • Excellent performance at high frequencies
    • ISO-17025 accredited calibration included with the standard
  10. RS Series Resistance Substitution Box
    • Accurate 0.1% to 1%
    • Wide range from 0.01 Ω - 100 MΩ (Depending on Model)
    • Broad choice of standard and optional models with many powerful features
    • Compact, convenient, and rugged
  11. GenRad 1433 Series Decade Resistor
    • Precision accuracy of 0.01%
    • Resistance range from 1 mΩ to 111.11111111 MΩ
    • 36 models available, 3 to 11 dials
    • Long life switches with silver-alloy contacts
  12. HRRS Series High Resistance Decade Box
    • Resistance from 100 Ω to 100 GΩ
    • High-accuracy: up to .01%, 3 Accuracy Classes Available
    • Voltage up to 2000 V
    • Excellent TC: as low as 5 ppm/°C
  13. PLS Series Programmable Inductance Decade Box
    • Wide range and resolution: 1 µH to 10 H
    • Available at accuracies of : 1% and 2%
    • LabVIEW Drivers for IEEE-488.2 and RS-232 Versions
    • Programmable "open circuit" and "short circuit" states optional
    • Desktop and 19" Rackmount enclosures
  14. PCS Series Programmable Capacitance Decade Box
    • The world's only programmable capacitance decade box
    • Wide range and resolution: 1 pF to 100 µF
    • Available at accuracies of : 0.5%, 1% and 4%
    • LabVIEW Drivers for IEEE-488.2 and RS-232 Versions
    • Dual / Combo rackmount models ( examples:Resistance & Capacitance )
  15. GenRad 1422 Series Variable Air Capacitors
    • Range as low as 0.002 pF and as high as 1150 pF (Depending on Model)
    • Stability: better than 0.02% full scale per year
    • Settable to 40 ppm
    • Low temperature coefficient, low losses
    • Wide selection to suit needs
  16. GenRad 1419 Series Decade Capacitor
    • Range from 100 pF to 1.1 µF
    • Choice of 3 models
    • Accuracy as good as 0.5%
    • Capacitance and dissipation factor vary only slightly with frequency from dc through the audio frequency range.
  17. HPRS Series High Power Resistance Decade Box
    • Resistance from 1 mΩ to 10 MΩ
    • Power Rating : 225 W/decade, 250 W max. or higher (contact IET for custom higher power units)
    • Accuracy: 0.5% or 1%
    • Special and custom configurations available
  18. RTD Series - Precision RTD Simulator
    • Highest accuracy, highest stability, lowest TC of any RTD Simulator available
    • Accuracy for Z Series: 0.005% (0.012 ºC for PT 100)
    • Resolution: 1 mΩ (0.0025 ºC for PT 100)
    • Stability 0.0002% for 24 hours; 0.001% for 12 months
  19. esi SR1 Calibration Resistor
    • New Design, with improved specifications
    • Versatile working calibration resistor
    • Laboratory standard of high accuracy and stability
    • Adjusted to within 20 ppm of nominal
    • 50 ppm long-term accuracy for most values
  20. DCCS DC Current Shunt Series
    • Allows for high current calibration, up to 60 A
    • Resistances ranges from 100 µΩ - 1 kΩ
    • High accuracy 0.02%
    • Suitable for direct current & audio frequencies
    • Oil-filled design ensures great long term stability <0.01% over many years
  21. GenRad 1546 Digital Stroboscope
    • High flashing rates for a stroboscope-up to 25,000 Fashes per minute, direct reading.
    • Flash duration from 1.2 μs to 2 μs for clear, crisp images.
    • Lightweight and handheld, very easy to use unit with digital readout
  22. GenRad 1557-A Vibration Calibrator
    • Single frequency 100 Hz
    • Single level 1 g
    • Calibration of vibration pickups with a mass less than 300 grams
    • Battery Operated
  23. esi SR1010 Resistance Transfer Standard
    • Resistance Transfer Standards available in the following values 1 Ω, 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ
    • Initial Accuracy... ± 20PPM of nominal value matched within 10PPM
    • Transfer Accuracy... ± (1PPM + 0.1uΩ at parallel value) for 100:1
    • Transfer Accuracy... ± (1PPM + 1uΩ at series parallel value) for 10:1
    • Long Term Accuracy... ± 50PPM of nominal value
    • Calibration Accuracy... ± 10PPM
  24. esi SR1030 Series Oil Immersed Transfer Standard
    • Resistance Values of 1 Ω - 100 kΩ
    • Initial Accuracy... ± 20 PPM of nominal value matched within 10 PPM
    • Transfer Accuracy... ± (1 PPM + 0.1uΩ at parallel value) for 100:1
    • Long Term Accuracy... ± 50 PPM of nominal value
    • Calibration Accuracy... ± 10 PPM
  25. SR102/103/104 Series
    • Highest accuracy (1 ppm/yr) and stability (±0.5 ppm/yr typical) of any resistance standard
    • Lowest temperature coefficients (< 0.1 ppm/ºC)
    • Available in 3 models: 100Ω, 1000 Ω, 10,000Ω.
    • Has remained the foremost resistance standard, with no equivalent, for over 35 years
    • 5 Year Warranty Included

Items 1-25 of 27

Page
per page
Set Descending Direction