Scrolling Catalog

Filter Ideal Instrument
  1. HACS-Z Series High Accuracy Decade Capacitance Box
    • Range from 1 pF to 11,111 µF
    • High accuracy of 0.05% + 0.5 pF
    • Units available with as few as 3 and as many as 11 decades
    • Excellent Stability 100 ppm per year
    • 3-Terminal shielded construction
  2. GenRad 1482 Series Inductance Standard
    • Stable within ±0.01% per year
    • 18 Models values from 1 µH to 10 H
    • Low, known temperature coefficient
    • 3 year warranty included
  3. GenRad 1409 Series Standard Capacitor
    • Values 0.001 µF (100 nF)  to 1000 µF
    • Stability as good as ±0.01 %/year
    • Two-to-five terminal configuration, depending on model
    • Calibration accredited to ISO-17025 included
    • 3 year warranty included
  4. PRS Series Programmable Resistance Decade Box
    • IEEE, RS232 or Ethernet Programmable Decade Resistor
    • Wide range and resolution: 1 mΩ to 100 MΩ
    • Available at accuracies of : 0.01%, 0.02%, 0.05%, 0.1%, 0.5%, and 1%
    • Special RTD and custom configurations
    • Dual / Combo rackmount models ( examples: resistance & capacitance )
    • Consider NEW PRS-300 Decade Resistor
  5. HARS-LX Series Decade Resistance Substituter Lab Standard
    • High accuracy - as good as 20 ppm
    • High stability - as good as 5 ppm/yr
    • Over 55 models available with resistance from 1 mΩ to 121.1 MΩ
    • Resolution as good 1 mΩ with a fixed decade or 20 μΩ with a rheostat.
  6. HRRS-5 kV & 10 kV Series - High Resistance Decade Box
    • Resistance from 10 Ω to 10 TΩ +
    • High-accuracy: up to .01%; 3 Accuracy Classes
    • Max voltage of 5 kV or 10 kV; 2 Series
    • Ideal for the calibration of meggers
  7. CS Series Cost Effective Capacitance Decade Box
    • Accurate 0.5% to 4%
    • Wide range from 50 pF - 1000 µF (depending on model)
    • Resolutions as good as 1 pF (depending on model)
    • Broad choice of standard and optional models with many powerful features
    • Compact, convenient, and rugged
  8. HARS Series Resistance Decade Box
    • Resistance from 1 mΩ to 111 MΩ
    • Available in double-power version: HARS-X2
    • Wide choice: single through 11 decade units
    • High accuracy - 0.01% (100 ppm) or 0.1% depending on model
  9. GenRad 1403 Series High Frequency Standard Capacitor
    • Available in values from 0.001 pF - 1000 pF
    • Excellent performance at high frequencies
    • ISO-17025 accredited calibration included with the standard
  10. LOM-510A Micro-Ohmmeter
    • 1 μΩ resolution, 4½ digits
    • Range: 1 μΩ - 200 Ω
    • 0.02% basic accuracy
    • Costs around 50% less then its peer instruments
  11. RS Series Resistance Substitution Box
    • Accurate 0.1% to 1%
    • Wide range from 0.01 Ω - 100 MΩ (Depending on Model)
    • Broad choice of standard and optional models with many powerful features
    • Compact, convenient, and rugged
  12. GenRad 1433 Series Decade Resistor
    • Precision accuracy of 0.01%
    • Resistance range from 1 mΩ to 111.11111111 MΩ
    • 36 models available, 3 to 11 dials
    • Long life switches with silver-alloy contacts
  13. HRRS Series High Resistance Decade Box
    • Resistance from 100 Ω to 100 GΩ
    • High-accuracy: up to .01%, 3 Accuracy Classes Available
    • Voltage up to 2000 V
    • Excellent TC: as low as 5 ppm/°C
  14. PLS Series Programmable Inductance Decade Box
    • Wide range and resolution: 1 µH to 10 H
    • Available at accuracies of : 1% and 2%
    • LabVIEW Drivers for IEEE-488.2 and RS-232 Versions
    • Programmable "open circuit" and "short circuit" states optional
    • Desktop and 19" Rackmount enclosures
  15. PCS Series Programmable Capacitance Decade Box
    • The world's only programmable capacitance decade box
    • Wide range and resolution: 1 pF to 100 µF
    • Available at accuracies of : 0.5%, 1% and 4%
    • LabVIEW Drivers for IEEE-488.2 and RS-232 Versions
    • Dual / Combo rackmount models ( examples:Resistance & Capacitance )
  16. GenRad 1422 Series Variable Air Capacitors
    • Range as low as 0.002 pF and as high as 1150 pF (Depending on Model)
    • Stability: better than 0.02% full scale per year
    • Settable to 40 ppm
    • Low temperature coefficient, low losses
    • Wide selection to suit needs
  17. esi RS925D Resistance Decade
    • High accuracy - 20 ppm + 0.5 mΩ
    • High stability - 20 ppm + 0.5 mΩ
    • Resistance from 10 mΩ to 1.1 MΩ
    • 20 μΩ resolution 
    • Precise fixed minimum resistance
  18. HPRS Series High Power Resistance Decade Box
    • Resistance from 1 mΩ to 10 MΩ
    • Power Rating : 225 W/decade, 250 W max. or higher (contact IET for custom higher power units)
    • Accuracy: 0.5% or 1%
    • Special and custom configurations available
  19. VRS-100 Series High Resistance Standards
    • Set of nine, ten or eleven resistors - 1 kΩ, 10 kΩ, 100 kΩ,1 MΩ, 10 MΩ, 100 MΩ, 1 GΩ, 10 GΩ, 100 GΩ, 1 TΩ and 10 TΩ , open circuit (Depending on model)
    • High Accuracy - up to 20 ppm
    • Standard voltage: up to 5 kV (voltages of 10 kV are available)
    • Excellent for calibration of Meggers
  20. esi SR1 Calibration Resistor
    • New Design, with improved specifications
    • Versatile working calibration resistor
    • Laboratory standard of high accuracy and stability
    • Adjusted to within 20 ppm of nominal
    • 50 ppm long-term accuracy for most values
  21. DCCS DC Current Shunt Series
    • Allows for high current calibration, up to 60 A
    • Resistances ranges from 100 µΩ - 1 kΩ
    • High accuracy 0.02%
    • Suitable for direct current & audio frequencies
    • Oil-filled design ensures great long term stability <0.01% over many years
  22. GenRad 1659 Digibridge
    • 0.1% measurement accuracy
    • 4 test frequencies 100 Hz to 10 kHz
    • 5 impedance parameters
    • Built-in test fixture
  23. GenRad 1620 Capacitance Bridge
    • 10-5pF to 11.1 µF, 2-or 3-terminal
    • frequency range 20 Hz -20 kHz (or higher)
    • 0.01% accuracy, 1-ppm resolution
    • reads dissipation factor or conductance
    • combines GenRad 1615 Capacitance Bridge, 1232-A Null Detector & 1311-A Oscillator
  24. GenRad 1692 Benchtop LCR Meter
    • 0.05% measurement accuracy
    • 5 test frequencies 100 Hz to 100 kHz
    • 5 impedance parameters
    • Built-in test fixture
  25. GenRad 1557-A Vibration Calibrator
    • Single frequency 100 Hz
    • Single level 1 g
    • Calibration of vibration pickups with a mass less than 300 grams
    • Battery Operated

Items 1-25 of 30

Page
per page
Set Descending Direction