Scrolling Catalog

Filter Ideal Instrument
  1. GenRad 1693 Precision LCR Meter
    • The world's standard for ac resistance, low frequency inductance and capacitance measurement in a metrology environment
    • 0.02% measurement accuracy and +/- 0.0001 Df
    • Programmable frequency 12 Hz - 200 kHz
    • Extremely reliable can last up to 30+ years
  2. GenRad 1482 Series Inductance Standard
    • Stable within ±0.01% per year
    • 18 Models values from 1 µH to 10 H
    • Low, known temperature coefficient
    • 3 year warranty included
  3. GenRad 1689 Precision Impedance Meter
    • The world's standard for AC resistance, low frequency inductance and Capacitance measurement
    • 0.02% Measurement Accuracy and +/- 0.0001 Df
    • Programmable Frequency 12 Hz - 100 kHz
    • Widely accepted impedance meter in a metrology environment
    • 1689 has a built-in 4 terminal kelvin fixture for testing axial and radial components
    • 1689M has four BNC connectors for use with a wide variety of standard accessories
  4. GenRad 1531-AB Stroboscope
    • High flashing rates up to 25,000 per minute — speed measurements to 250.000 rpm.
    • Short flash duration — "stops" rapid motion and permits ultra-high-speed photography.
    • High accuracy stroboscope — rpm measurements can be made to ± 1%.
  5. GenRad 1409 Series Standard Capacitor
    • Values 0.001 µF (100 nF)  to 1000 µF
    • Stability as good as ±0.01 %/year
    • Two-to-five terminal configuration, depending on model
    • Calibration accredited to ISO-17025 included
    • 3 year warranty included
  6. GenRad 1491 D, G Precision Decade Inductor
    • Most accurate decade inductor commercially available, accuracy's as good as 0.8%
    • Inductance range from 1 mH or 100 µH to 11 H
    • Shielded toroidal cores for small mutual inductance and minimal effect from external fields
    • Sealed against moisture for long-term stability
  7. GenRad 1404 Series Primary Standard Capacitors
    • Available in 10 pF, 100 pF,1000 pF, 5000 pF 10,000 pF
    • 20 ppm/year stability, history has shown this to be a very conservative specification
    • The national laboratory standard for capacitance
    • For calibrating highest level standards
    • Standard for dissipation factor
    • 5 year warranty included 
  8. Genrad 1413 Precision Decade Capacitor
    • Range from 1 pF to 1.11111 µF
    • High accuracy of 0.05% + 0.5 pF
    • Excellent Stability 100 ppm per year
    • The trusted lab standard for capacitance
    • 3-Terminal shielded construction
  9. GenRad 1986 Omnical Sound Level Calibrator -Refurbished
    • Capable of testing all the basic characteristics of virtually any acoustic instrument or system
    • Multi-level outputs 74, 84, 94, 104, or 114 dB re 20µPa output
    • Multi-frequency outputs 125, 250, 500, 1000, 2000 or 4000 Hz
    • Portable battery-operated
  10. GenRad 1863 Megohmmeter
    • Rugged and portable analog megohmmeter
    • Up to 3% accuracy
    • 5 Test voltages from 50, 100, 200, 250, 500 Vdc
    • 50 kΩ to 20 TΩ measurement range
    • Maximum of 5 mA charge current
    • Analog output
  11. GenRad 1403 Series High Frequency Standard Capacitor
    • Available in values from 0.001 pF - 1000 pF
    • Excellent performance at high frequencies
    • ISO-17025 accredited calibration included with the standard
  12. GenRad 1433 Series Decade Resistor
    • Precision accuracy of 0.01%
    • Resistance range from 1 mΩ to 111.11111111 MΩ
    • 36 models available, 3 to 11 dials
    • Long life switches with silver-alloy contacts
  13. 1455 Series Decade Voltage Divider
    • Linearity better than 20 ppm (5-dial model) 
    • Input impedance: for 1455-A 10 kΩ & 1455-B, 1455-BH 100 kΩ 
    • High-frequency model, down 3 dB at 7.5 MHz
  14. GenRad 1423-A Decade Capacitor
    • Range 100pF - 1.111 µF
    • ±0.05% accuracy
    • two- or three-terminal connection
  15. GenRad 1422 Series Variable Air Capacitors
    • Range as low as 0.002 pF and as high as 1150 pF (Depending on Model)
    • Stability: better than 0.02% full scale per year
    • Settable to 40 ppm
    • Low temperature coefficient, low losses
    • Wide selection to suit needs
  16. GenRad 1412-BC Decade Capacitance Box
    • Range from 50 pF to 1.11115 µF
    • Resolution better than 1 pF
    • Accuracy 0.5% + 5 pF
    • Low loss, leakage, dielectric absorption
    • Verification of calibration of LCR meters, multimeters, and instrumentation
  17. GenRad 1417 Capacitance Standard 1 uF - 1 F
    • 7 Switch-Selected Standard Capacitance Values: 1 µF, 10 µF, 100 µF, 1 mF, 10 mF,100 mF, 1 F
    • 3 Switch-Selected Test Frequencies: 100 Hz,
      120 Hz, 1 kHz
    • 0.25% direct-reading capacitance accuracy
    • 0.1% or better ratio accuracy
  18. GenRad 1419 Series Decade Capacitor
    • Range from 100 pF to 1.1 µF
    • Choice of 3 models
    • Accuracy as good as 0.5%
    • Capacitance and dissipation factor vary only slightly with frequency from dc through the audio frequency range.
  19. GenRad 1565-B Sound-Level Meter
    • 40 to 140 dB
    • ANSI Type 2 A, B, C weighting
    • Fast/slow meter response
    • MESA approved
    • Convenient pocket proportions -small and light
  20. GenRad 1659 Digibridge
    • 0.1% measurement accuracy
    • 4 test frequencies 100 Hz to 10 kHz
    • 5 impedance parameters
    • Built-in test fixture
  21. GenRad / QuadTech 1864-9700 Megohmmeter
    • 200 Test voltages from 10 V to 1090 Vdc
    • Rugged and portable analog megohmmeter
    • Up to 3% accuracy
    • 50 kΩ to 200 TΩ measurement range
    • Reliable high quality instrument designed to last up to 30 years
  22. GenRad 1620 Capacitance Bridge
    • 10-5pF to 11.1 µF, 2-or 3-terminal
    • frequency range 20 Hz -20 kHz (or higher)
    • 0.01% accuracy, 1-ppm resolution
    • reads dissipation factor or conductance
    • combines GenRad 1615 Capacitance Bridge, 1232-A Null Detector & 1311-A Oscillator
  23. GenRad 1692 Benchtop LCR Meter
    • 0.05% measurement accuracy
    • 5 test frequencies 100 Hz to 100 kHz
    • 5 impedance parameters
    • Built-in test fixture
  24. GenRad 1621 Capacitance Bridge
    • Range 10-7 pF to 10 µF, 12-digit readout
    • 10-ppm basic accuracy
    • frequency range 10 Hz - 100 kHz
    • combines GenRad 1616 Capacitance Bridge, 1238-A Null Detector & 1316 Oscillator
  25. GenRad 1542 Stroboscope
    • Low-cost, excellent US Manufactured stroboscope for stopping motion
    • Up to 3800 bright-white flashes per minute -to observe motion as fast as 40,000 rpm
    • Simple push-button operation
    • Compact, light-weight, rugged

Items 1-25 of 33