7600 Plus Precision LCR Meter (DISCONTINUED REPLACED BY 7660)
- Measures 14 impedance parameters (2 simultaneously)
- 0.05% Basic measurement accuracy
- Programmable frequencies from 10 Hz to 2 MHz
- AC test voltage programmable from 20 mV to 5 V
- DC bias voltage, 2 V internal or 0 to 200 V external
- Fast measurement speeds up to 120/second
- Automatic open/short zeroing eliminates connection errors
- High resolution LCD with 7 digit display
- 14 Hi/Lo sorting bins for pass/fail testing
GenRad 1620 Capacitance Bridge
- 10-5pF to 11.1 µF, 2-or 3-terminal
- frequency range 20 Hz -20 kHz (or higher)
- 0.01% accuracy, 1-ppm resolution
- reads dissipation factor or conductance
- combines GenRad 1615 Capacitance Bridge, 1232-A Null Detector & 1311-A Oscillator
GenRad 1621 Capacitance Bridge
- Range 10-7 pF to 10 µF, 12-digit readout
- 10-ppm basic accuracy
- frequency range 10 Hz - 100 kHz
- combines GenRad 1616 Capacitance Bridge, 1238-A Null Detector & 1316 Oscillator
GenRad 1659 Digibridge
- 0.1% measurement accuracy
- 4 test frequencies 100 Hz to 10 kHz
- 5 impedance parameters
- Built-in test fixture
GenRad 1689 Precision Impedance Meter
- The world's standard for AC resistance, low frequency inductance and Capacitance measurement
- 0.02% Measurement Accuracy and +/- 0.0001 Df
- Programmable Frequency 12 Hz - 100 kHz
- Widely accepted impedance meter in a metrology environment
- 1689 has a built-in 4 terminal kelvin fixture for testing axial and radial components
- 1689M has four BNC connectors for use with a wide variety of standard accessories
GenRad 1693 Precision LCR Meter
- The world's standard for ac resistance, low frequency inductance and capacitance measurement in a metrology environment
- 0.02% measurement accuracy and +/- 0.0001 Df
- Programmable frequency 12 Hz - 200 kHz
- Extremely reliable can last up to 30+ years
IET 7660 Precision LCR Meter
- Measures 14 impedance parameters (2 simultaneously)
- 0.05% Basic measurement accuracy
- Programmable frequencies from 10 Hz to 2 MHz
- AC test voltage programmable from 20 mV to 5 V
- DC bias voltage, 2 V internal or 0 to 200 V external
- Fast measurement speeds up to 120/second
- Automatic open/short zeroing eliminates connection errors
- High resolution LCD with 7 digit display
- 14 Hi/Lo sorting bins for pass/fail testing
IET/QuadTech 1910/1920 1 MHz LCR Meter
- 20 Hz to 1 MHz frequency range 27,000 possible frequency options
- 0.1% basic measurement accuracy
- Measures 15 impedance parameters, dc resistance, voltage and current
- IEEE-488.2,RS-232, handler, and serial printer interfaces all standard
- Wide measurement range with 5 digit measurement resolution