Capacitance Bridges

  1. GenRad 1689 Precision Impedance Meter
    • The world's standard for AC resistance, low frequency inductance and Capacitance measurement
    • 0.02% Measurement Accuracy and +/- 0.0001 Df
    • Programmable Frequency 12 Hz - 100 kHz
    • Widely accepted impedance meter in a metrology environment
    • 1689 has a built-in 4 terminal kelvin fixture for testing axial and radial components
    • 1689M has four BNC connectors for use with a wide variety of standard accessories
  2. IET/QuadTech 7600 Plus Precision LCR Meter
    • Measures 14 impedance parameters (2 simultaneously)
    • 0.05% basic measurement accuracy
    • Programmable frequencies from 10 Hz to 2 MHz
    • AC test voltage programmable from 20 mV to 5 V
    • DC bias voltage, 2 V internal or 0 to 200 V external
    • Fast measurement speeds up to 120/second
    • Automatic open/short zeroing eliminates connection errors
    • High resolution LCD with 7 digit display
    • 14 Hi/Lo sorting bins for pass/fail testing
  3. IET/QuadTech 1910/1920 1 MHz LCR Meter
    • 20 Hz to 1 MHz frequency range 27,000 possible frequency options
    • 0.1% basic measurement accuracy
    • Measures 15 impedance parameters, dc resistance, voltage and current
    • IEEE-488.2,RS-232, handler, and serial printer interfaces all standard
    • Wide measurement range with 5 digit measurement resolution
    • Four-terminal Kelvin connections to maintain measurement integrity
  4. GenRad 1693 Precision LCR Meter
    • The world's standard for ac resistance, low frequency inductance and capacitance measurement in a metrology environment
    • 0.02% measurement accuracy and +/- 0.0001 Df
    • Programmable frequency 12 Hz - 200 kHz
    • Extremely reliable can last up to 30+ years
  5. GenRad 1620 Capacitance Bridge
    • 10-5pF to 11.1 µF, 2-or 3-terminal
    • frequency range 20 Hz -20 kHz (or higher)
    • 0.01% accuracy, 1-ppm resolution
    • reads dissipation factor or conductance
    • combines GenRad 1615 Capacitance Bridge, 1232-A Null Detector & 1311-A Oscillator
  6. GenRad 1692 Benchtop LCR Meter
    • 0.05% measurement accuracy
    • 5 test frequencies 100 Hz to 100 kHz
    • 5 impedance parameters
    • Built-in test fixture
  7. GenRad 1659 Digibridge
    • 0.1% measurement accuracy
    • 4 test frequencies 100 Hz to 10 kHz
    • 5 impedance parameters
    • Built-in test fixture
  8. GenRad 1621 Capacitance Bridge
    • Range 10-7 pF to 10 µF, 12-digit readout
    • 10-ppm basic accuracy
    • frequency range 10 Hz - 100 kHz
    • combines GenRad 1616 Capacitance Bridge, 1238-A Null Detector & 1316 Oscillator

8 Items

per page