Scrolling Catalog
-
GenRad 1693 Precision LCR Meter
- The world's standard for AC Resistance, Low Frequency Inductance and Capacitance measurement in a metrology environment
- 0.02% Measurement Accuracy and +/- 0.0001 Df
- Programmable Frequency 12 Hz - 200 kHz
- Extremely Reliable can last up to 30+ years
-
GenRad 1482 Series Inductance Standard
- Stable within ±0.01% per year
- 18 Models values from 1 µH to 10 H
- Low, known temperature coefficient
- 3 year warranty included
-
GenRad 1689 Precision Impedance Meter
- The world's standard for AC Resistance, Low Frequency Inductance and Capacitance measurement
- 0.02% Measurement Accuracy and +/- 0.0001 Df
- Programmable Frequency 12 Hz - 100 kHz
- Widely accepted impedance meter in a metrology environment
- 1689 has a built-in 4 terminal kelvin fixture for testing axial and radial components
- 1689M has four BNC connectors for use with a wide variety of standard accessories
-
GenRad 1531-AB Stroboscope
- High flashing rates up to 25,000 per minute — speed measurements to 250.000 rpm.
- Short flash duration — "stops" rapid motion and permits ultra-high-speed photography.
- High accuracy stroboscope — rpm measurements can be made to ± 1%.
-
GenRad 1409 Series Standard Capacitor
- Values 0.001 µF (100 nF) to 1000 µF
- Stability as good as ±0.01 %/year
- Two-to-five terminal configuration, depending on model
- Calibration accredited to ISO-17025 included
- 3 year warranty included
GenRad 1491 D, G Precision Decade Inductor
- Most accurate decade inductor commercially available, accuracy's as good as 0.8%
- Inductance range from 1 mH or 100 µH to 11 H
- Shielded toroidal cores for small mutual inductance and minimal effect from external fields
- Sealed against moisture for long-term stability
GenRad 1404 Series Primary Standard Capacitors
- A national laboratory standard
- For calibrating working standards
- Standard for dissipation factor
- Available in 10 pF, 100 pF,1000 pF, 10,000 pF
- 5 Year Warranty Included
Genrad 1413 Precision Decade Capacitor
- Range from 1 pF to 1.11111 µF
- High accuracy of 0.05% + 0.5 pF
- Excellent Stability 100 ppm per year
- The trusted lab standard for capacitance
- 3-Terminal shielded construction
GenRad 1986 Omnical Sound Level Calibrator -Remanufactured
- Capable of testing all the basic characteristics of virtually any acoustic instrument or system
- Multi-level outputs 74, 84, 94, 104, or 114 dB re 20µPa output
- Multi-frequency outputs 125, 250, 500, 1000, 2000 or 4000 Hz
- Portable battery-operated
GenRad 1863 Megohmmeter
- Rugged and Portable Analog Megohmmeter
- Up to 3% Accuracy
- 5 Test Voltages from 50, 100, 200, 250, 500 VDC
- 50 kΩ to 20 TΩ Measurement Range
- Maximum of 5 mA Charge Current
- Analog Output
GenRad 1403 Series High Frequency Standard Capacitor
- Available in values from 0.001 pF - 1000 pF
- Excellent Performance at high frequencies
- ISO-17025 Accredited Calibration Included with the Standard
GenRad 1433 Series Decade Resistor
- Precision accuracy of +0.01%
- Resistance range from 1 mΩ to 111.11111111 MΩ
- 36 models available, 3 to 11 dials
- Long life switches with solid silver contacts
- Excellent frequency characteristics
1455 Series Decade Voltage Divider
- Linearity better than 20 ppm (5-dial model)
- Input impedance: for 1455-A 10 kΩ & 1455-B, 1455-BH 100 kΩ
- High-frequency model, down 3 dB at 7.5 MHz
GenRad 1423-A Decade Capacitor
- Range 100pF - 1.111 µF
- ±0.05% accuracy
- two- or three-terminal connection
GenRad 1422 Series Variable Air Capacitors
- Range as low as 0.002 pF and as high as 1150 pF (Depending on Model)
- Stability: better than 0.02% full scale per year
- Settable to 40 ppm
- Low temperature coefficient, low losses
- Wide selection to suit needs