- SRX-NI-4082 Standard Resistor Calibration Set
- Owned used and recommend by National Instruments
- Very stable - drift < 50 ppm/yr
- Excellent temperature coefficient - 2 ppm/°C
- Rugged
- Set consists of 4 resistance standards: 25 Ω, 125 Ω, 5 kΩ, 100 kΩ values as recommended by NI PXIe-408x calibration procedure
- 3/4" spacing for direct connection to the NI PXIe-4082
- Low inductance < 0.08 µH
- Accredited Calibration
- In addition to the standard values, any custom value is available. Please contact the IET sales department, for more information
- 1865+ Megohmmeter- Discontinued Replaced by the 1888
Discontinued becuase of parts obsolense as of July 2024
Replaced by the more accuracte easier to use 1888
CLICK HERE FOR THE 1888 Megohmeter
IET can still calibrate and repair most issues
- GenRad 1689 Precision Impedance Meter
- The world's standard for AC resistance, low frequency inductance and Capacitance measurement
- 0.02% Measurement Accuracy and +/- 0.0001 Df
- Programmable Frequency 12 Hz - 100 kHz
- Widely accepted impedance meter in a metrology environment
- 1689 has a built-in 4 terminal kelvin fixture for testing axial and radial components
- 1689M has four BNC connectors for use with a wide variety of standard accessories
- PRS-200 Series Programmable Resistance Decade Box
- IEEE, RS232 or Ethernet Programmable Decade Resistor
- Wide range and resolution: 1 mΩ to 100 MΩ
- Available at accuracies of : 0.01%, 0.02%, 0.05%, 0.1%, 0.5%, and 1%
- Special RTD and custom configurations
- Dual / Combo rackmount models ( examples: Resistance & Capacitance or Resistance & Inductance)
- VI-700 Precision Voltage & Current Source (Discontinued)
- Discontinued
- Voltage output range of 100 µV to 20 V or 200 V
- Current output range of 0.1 µA to 20 mA or 200 mA
- 3½ digit resolution, 0.75 LSD accuracy
- Manual thumbwheel operation or programmable digital input, IEEE-488 or RS232 interface
- May be used as a component in a closed loop control system
- Manufactured in the United States
- GenRad 1404 Series Primary Standard Capacitors
- Available in 10 pF, 100 pF,1000 pF, 5000 pF 10,000 pF
- 20 ppm/year stability, history has shown this to be a very conservative specification
- The national laboratory standard for capacitance
- For calibrating highest level standards
- Standard for dissipation factor
- 5 year warranty included
- esi DP 1211 & DP 1311 Voltage Dividers (Discontinued)
- Discontinued
- Kelvin-Varley voltage divider
- Still manufactured to the same specifications as esi/Tegam units
- 4 standard models with resistance values of 1 kΩ & 10 kΩ
- Custom resistance values, like 8 kΩ or 100 kΩ are available
- Precision resistors throughout
- Solid silver-alloy switch contacts
- HRRS-5 kV & 10 kV Series - High Resistance Decade Box
- Choose from units with a max. resistance of 1 GΩ, 10 GΩ, 10 GΩ, 1TΩ or 11 TΩ
- Units use the most stable and accurate resistors and custom high voltage switches
- Maximum Voltages of 5000 V or 10,000 V. For 2000 V, consider the standard HRRS Series
- Used for calibration of Meggers and sourcing out precision high resistance.